C
HAPTER
1
vi
ISO Product Controller II and Hawkeye Operation Manual
PRESSURE SETTINGS
UNIT DEFINITIONS AND CONVERSIONS
UNIT OF MEASURE DEFINITIONS
UNIT OF MEASURE CONVERSIONS
To convert the meter cal value into the selected unit of measure, divide the original number printed on the flow
meter label by the desired conversion value.
Response
Rate
Min.
Pressure
Max.
Pressure
0-250 psi or
0-150 psi
Abbreviation
Definition
Abbreviation
Definition
GPM
Gallons per Minute
dm
Decimeters
lit/min
Liters per Minute
m
Meter
dl/min
Deciliters per Minute
MPH
Miles per Hour
PSI
Pounds per Square Inch
km
Kilometers
kPa
Kilopascal
km/h
Kilometers per Hour
GPA
Gallons per Acre
US
Volume per Acre
lit/ha
Liters per Hectare
SI
Volume per Hectare
ml/ha
Milliliters per Hectare
TU
Volume per 1,000 Square Feet
GPK
Gallons per 1,000 Square Feet
[ ]
Metric Numbers
mm
Millimeters
lb/acre
Pounds per Acre
cm
Centimeters
kg/ha
Kilograms per Hectare
Fluid Ounces Conversion
Formula
Liters Conversion Formula
Pounds Conversion Formula
Liquid
Area
• 1 U.S gallon = 128 fluid ounces
• 1 square meter = 10.764 square feet
• 1 U.S. gallon = 3.785 liters
• 1 hectare = 2.471 acres or 10,000 square meters
• 1 U.S. gallon = 0.83267 imperial gallons
• 1 acre = 0.405 hectares or 43,560 square feet
• 1 U.S. gallon = 8.34 pounds (water)
• 1 square mile = 640 acres or 258.9 hectares
• 1 U.S. gallon = 10.67 pounds (28% N)
Original Meter Cal
128
Original Meter Cal
3.785
Original Meter Cal
Weight of One Gallon of
Summary of Contents for Hawkeye
Page 10: ...CHAPTER 1 viii ISO Product Controller II and Hawkeye Operation Manual ...
Page 16: ...CHAPTER 1 6 ISO Product Controller II and Hawkeye Operation Manual ...
Page 22: ...CHAPTER 2 12 ISO Product Controller II and Hawkeye Operation Manual ...
Page 50: ...CHAPTER 4 40 ISO Product Controller II and Hawkeye Operation Manual ...
Page 92: ...APPENDIX A 82 ISO Product Controller II and Hawkeye Operation Manual ...
Page 95: ...P N 016 0171 584 H 85 FIGURE 3 Generic Cabling for Self Propelled Sprayer ...
Page 97: ...P N 016 0171 584 H 87 FIGURE 5 Generic Cabling for Pull Type Sprayer with Existing Raven CAN ...
Page 99: ...P N 016 0171 584 H 89 FIGURE 7 20 Spacing Generic Cabling ...
Page 111: ...P N 016 0171 584 H 101 ...
Page 112: ...APPENDIX D 102 ISO Product Controller II and Hawkeye Operation Manual ...
Page 116: ...APPENDIX E 106 ISO Product Controller II and Hawkeye Operation Manual ...
Page 120: ...APPENDIX F 110 ISO Product Controller II and Hawkeye Operation Manual ...
Page 128: ...APPENDIX G 118 ISO Product Controller II and Hawkeye Operation Manual ...
Page 134: ...APPENDIX H 124 ISO Product Controller II and Hawkeye Operation Manual ...