4
Hawkeye® Nozzle Control and Sidekick Pro ICD Setup: Tools Menu Settings Definitions
27
HAWKEYE® NOZZLE CONTROL AND SIDEKICK PRO ICD SETUP
To recalibrate the turn compensation feature:
1. Move the equipment to a known level location.
2. Open the UT Menu and select the Hawkeye
®
Menu button.
3. Select the Tools Menu softkey along the right side of the display.
4. Select the System Settings tab along the top of the display.
5. Select the User Settings button and then select the Cal Gyro button. The system will recalibrate the Hawkeye
Product Controller II ECU gyro and set the node orientation.
ENABLE WIRELESS CONTROL
Enable the wireless control feature to control pump, section valves, and nozzles along with performing remote
diagnostic applications, using a Bluetooth low energy device when outside the cab.
OVERRIDE SECONDS
Use the override seconds value to set the time which the system should override automatic section commands
and keep sections on. This feature may be used when starting application with the equipment at a complete stop,
or to manually override all sections on for the set number of seconds.
NOTE:
The default on override value is 15 seconds. The override seconds valve can only be changed outside
of a job from this location. If the user desired to change this value while in a job, use the on screen
override widget on the Viper 4.
The override will only activate sections set for automatic section control. Any sections configured for
manual control, or set on or off manually, will not be affected by the AccuBoom Override feature.
SPEED CAL
Enter the Speed Cal value of the radar speed sensor (if equipped). Refer to the radar manufacturer’s specification
for recommended value and perform distance calibration to ensure accuracy.
IMPLEMENT SWITCH
The implement switch senses the position of the toolbar and turns application off when raised and enables
application when lowered.
NOTE:
Speed Cal value may not be present on systems that display a Boom Sense/Speed Menu Icon on the
UT.
NCV PERFORMANCE
The NCV performance indicator displays the current System Efficiency value and High, Average, and Low NCV
duty cycles for any active NCV's. These values can be displayed on the lower home screen if the system is
equipped with NCV's and there are less than three injection products connected to the system.
For information on the System Efficiency value, refer to the “System Settings Tab - Alarm” on page 30.
Hawkeye
Menu
Tools Menu
System
Settings
User
Settings
Cal Gyro
UT Menu
Summary of Contents for Hawkeye
Page 10: ...CHAPTER 1 viii ISO Product Controller II and Hawkeye Operation Manual ...
Page 16: ...CHAPTER 1 6 ISO Product Controller II and Hawkeye Operation Manual ...
Page 22: ...CHAPTER 2 12 ISO Product Controller II and Hawkeye Operation Manual ...
Page 50: ...CHAPTER 4 40 ISO Product Controller II and Hawkeye Operation Manual ...
Page 92: ...APPENDIX A 82 ISO Product Controller II and Hawkeye Operation Manual ...
Page 95: ...P N 016 0171 584 H 85 FIGURE 3 Generic Cabling for Self Propelled Sprayer ...
Page 97: ...P N 016 0171 584 H 87 FIGURE 5 Generic Cabling for Pull Type Sprayer with Existing Raven CAN ...
Page 99: ...P N 016 0171 584 H 89 FIGURE 7 20 Spacing Generic Cabling ...
Page 111: ...P N 016 0171 584 H 101 ...
Page 112: ...APPENDIX D 102 ISO Product Controller II and Hawkeye Operation Manual ...
Page 116: ...APPENDIX E 106 ISO Product Controller II and Hawkeye Operation Manual ...
Page 120: ...APPENDIX F 110 ISO Product Controller II and Hawkeye Operation Manual ...
Page 128: ...APPENDIX G 118 ISO Product Controller II and Hawkeye Operation Manual ...
Page 134: ...APPENDIX H 124 ISO Product Controller II and Hawkeye Operation Manual ...