![background image](http://html.mh-extra.com/html/raven/autoboom/autoboom_calibration-and-operation-manual_788802031.webp)
Manual No. 016-0130-076 Rev. C
27
Operation
AutoBoom
®
Widget and Control Prompt
The AutoBoom widget allows the operator to engage and disengage boom sections quickly right from the
guidance display. The widget also provides access to AutoBoom system power and operational adjustments.
Status Display and Interface
The AutoBoom widget displays the following system and boom status information:
Note:
The center rack status will only be displayed if the Center Rack Control
feature is selected. Review the AutoBoom® Features Tab section on page 14 for
additional information regarding features available with the Raven AutoBoom
system.
System Off.
When the AutoBoom system power is off, all boom sections will display a red x as shown in the
figure above. The system power must be toggled on before AutoBoom height control may be enabled for
boom sections. See the
section on page 27 for assistance with toggling the
AutoBoom system power.
Boom Disabled.
AutoBoom height control is not enabled for any sections displayed in red as shown in the
figure above. Touch the status indicator to enable AutoBoom for that section.
Note:
If XT Control is available, disabling height control for either the left or right boom section will
automatically disable automated center rack XT control functions.
Boom Enabled.
AutoBoom height control is enabled for any sections displayed in green as shown in the
figure above. Touch the status indicator to disable AutoBoom for that section.
Note:
Enabling height control for the center rack section will automatically enable the left and right boom
sections.
Boom Calibrate.
Any sections for which the automated calibration has not been completed
will display the boom calibrate status.
While boom sections may be calibrated during a job in many circumstances, it is highly
recommended to exit the job and calibrate the AutoBoom system from the Calibrate Tab
within the AutoBoom module. Review Chapter 3,
, for additional information and
detailed procedures.
AutoBoom
®
System Power
To toggle the AutoBoom system power while in an active job:
1.
Touch and hold the AutoBoom widget for approximately 2 seconds to access the AutoBoom in-job prompt.
2.
Touch the Master Power icon to toggle the AutoBoom system on or off.
WARNING
AutoBoom may adjust boom height
unexpectedly. Turn the AutoBoom system off
when leaving the operator position or exiting the
implement cabin.
System
Off
Boom
Disabled
Boom
Enabled
Calibration
Required
AutoBoom
Widget