INSTRUCTION, USE AND
MAINTENANCE MANUAL
Calibration of external data gauge (standard on
some models)
Press the button
to display the following screen
page on the monitor:
TO PERFORM THIS CALIBRATION,
THE CHUCK MUST BE UNLOADED
(NO WHEEL OR ACCESSORIES
MOUNTED ON IT) AND WITH
CLOSED PNEUMATIC CHUCK.
Move the tip of the width measuring device (
Fig. 79
- Fig. 80 ref. 1
) by the chuck end (
Fig. 79 - Fig. 80
ref. 2
) (in case of pneumatic chuck, move it next to
upper edge of the closed chuck).
THREADED CHUCK
Fig. 79
PNEUMATIC CHUCK
THREADED CHUCK
Fig. 80
(OPTIONAL)
PNEUMATIC CHUCK
Press button
.
On the monitor the next screen page will be displayed:
RAVAGLIOLI S.p.A.
1297-M005-03
G4.140R - G4.140WS - G4.140WSLB - GP4.140WS