EN
Page 48 of 77
INSTRUCTION, USE AND
MAINTENANCE MANUAL
Press button
to select such procedure and bring
automatically the wheel into weight fitting position.
1
2
3
4 5
6
KEY
1 – Only weight to be fitted
2 – Last program and last values used for the spin
3 – Residual dynamic unbalance value (if the value
is blue it is not to carry out ECO-WEIGHT pro-
cedure)
4 – Static unbalance value (if the value is blue it is
not to carry out ECO-WEIGHT procedure)
5 – Residual dynamic unbalance value (if the value
is blue it is not to carry out ECO-WEIGHT pro-
cedure)
6 – Arrows indicating the weight fitting point with
distance-diameter caliper arm
Fig. 63
Press the brake pedal and fit the adhesive weight inside
pliers as shown in
Fig. 64
.
Fit the adhesive weight
in the pliers of the gauge rod
Fig. 64
Pull out the gauge rod until the arrows (
Fig. 63 ref. 6
)
turn green.
Fig. 65
Fit weight on the position
where pliers touches the wheel
At the end of the procedure, the wheel balancing condi-
tions can be checked by performing a trial spin.
The ECO-WEIGHT procedure has now been completed.
RAVAGLIOLI S.p.A.
1297-M005-03
G4.140R - G4.140WS - G4.140WSLB - GP4.140WS