Fig. 55: Adjusting the TELIMAT unit
[1]
Sliding section
[2]
Numeric scale for fine adjustment
[3]
Guiding plate
[4]
Adjustment nut for alphabetic scale
[5]
Adjustment nut for numeric scale
[6]
Alphabetic scale for coarse adjustment
•
The complete TELIMAT housing can be rotated in guides around the spreading disc hub
(alphabetic scale H to Z). The alphabetic scale is used to adjust the housing according to the
respective fertilizer type and spreading type (limited or full border spreading).
•
One-piece guiding plates are available inside the boundary spreading unit and can be moved
along a numeric scale (scale 1 to 7). The numeric scale is mainly used for setting the working
width.
Coarse adjustment (alphabetic scale)
u
Loosen the adjustment nut for the alphabetic scale using the adjustment lever of the machine.
u
Slide the TELIMAT housing (sliding section) onto the letter prescribed by the calibration chart.
The arrow is exactly above the specified letter.
u
Tighten the adjustment nut for the alphabetic scale using the adjustment lever of the machine.
The coarse adjustment is finished and is refined with the fine adjustment.
9. Spreading operation
MDS 8.2/14.2/18.2/20.2
5902916
97