Settings
3
10
NOTICE
The main settings for the AXMAT function are described here. Further information
on operating the machine control unit is provided in the operating manual provided
with the unit.
Submenu
Meaning/possible values
Description
Fertiliser name
Fertiliser selected from the fertiliser
chart
Appl. rate. (kg/ha)
Input of target value for the application
rate in kg/ha
Working width (m)
Determination of the working width to
be spread
Drop point
The drop point cannot be entered
when the AXMAT function is activated
Normal disc speed
Input of the desired spreading disc
speed
Influences the EMC mass flow control
Spreading disc
Setting of the spreading disc type
mounted at the mineral fertiliser
spreader
(influences the EMC mass flow
control)
Selection list:
S4
S6
S8
S10
S12
Fertiliser class
Selection list
Fertiliser chart
Management of fertiliser charts
Calibrating AXMAT
Definition of the target values for regu-
lating the drop point during spreading
operation