Settings
3
12
3.3.4
Normal disc speed
1.
Call up the
Fertiliser settings > Normal speed
menu.
2.
Enter speed in rpm.
The display shows the Fertiliser settings window with the new speed.
3.3.5
Fertiliser class
If you know the fertiliser class, enter this directly.
If you do not know the fertiliser class of the fertiliser used, you can determine this
using the "fertiliser identification system
DIS
" special equipment.
Figure 3.3:
Fertiliser settings, page 3
1.
Call up the
Main menu > Fertiliser settings
menu.
2.
Call up the
Fertiliser class
[1] menu entry.
3.
Activate the corresponding fertiliser class in the selection list.
NOTICE
For
optimal empty run measurement
you must check for correct entries in the
Fertiliser settings
menu.
The values in the
Disc
and
Normal speed
menu entries must agree with the
actual settings of your machine.
NOTICE
The "fertiliser identification system
DIS
" is available in the
Fertiliser Chart App
.
1