Minimum charging
Set the minimum required charging current of the charger.
current
Range: 6A - 16A.
Maximum charging
Set the maximum required charging current of the charger.
current
Range: 6A – 32A.
Charge mode
Set the desired charge mode.
Note:
See chapter 2. for more information on the charge modes.
SmartSolar starting
Set the minimum required charging current of the
current
charger for the SmartSolar charge mode
Range:
6A
–
10A.
PureSolar starting
Set the minimum required charging current of the
current
charger for the PureSolar charge mode.
Range:
6A
–
16A.
Sun off Delay
Set a delay time for the charger to stop charging
after net current generation is no longer detected.
Range:
2
min
–
60
min.
Sun on Delay
Set a charging delay time after net current
generation is detected (e.g. from solar panels).
Range:
1
min
–
20
min.