5.8 Install a data cable between two chargers for Power Sharing
5.8.1. In the Main Controller
1.
Install a data cable between the “Main” charger and “Sub 1” charger.
2.
Remove the terminal connector of the existing data cable from the charger.
3.
Guide the second data cable alongside the existing data cable through the cable gland
or rubber grommet.
4.
Strip the wires of the data cable.
5.
Match the coloured wires to the wires already used in the Sensor Box RJ10 connector.
6.
Remove any unused cores.
7.
Insert the wires into a second RJ10 connector.
8.
Secure the wires to the terminals using a RJ10 crimping tool.
9.
Insert the RJ10 connector into the right RJ10 connector of the charger.
10.
Gently pull the excess data cable out of the charger.