background image

ALL APPLICATIONS (VENTED and VENT FREE OPERATION)

Log Placement (cont.)

Pilot

Burner

Pilot

Ember

Lifter

REAR  LOG

Rear Bracket

C 7

Pilot

Ember

Lifter

Burner

FRONT LOG (1)

FRONT LOG (2)

D F C 7

Pilot

EMBER MATERIAL:  With the FRONT and REAR
LOGS
 on the Grate as shown, pull apart the E M B E R
MATERIAL
 into long loose, thin pieces and drape
them over the EMBER LIFTER. The pieces should
be no more than one to two pieces of ember
material in depth
.  To enhance ember performance,
after approximately 5 minutes of burn time,  gently loosen
and lift EMBER MATERIAL.

NOTE: Thinner, less densely packed Ember Material
pieces enhance the overall glowing ember effect. The
looser the pieces, the better the glowing ember effect!

   .

Pilot

Burner

Pilot

Position

Ember Material Recomended Actual Size

Ember
Lifter

Burner

WARNING: Excessive amounts of Ember Material or Ember Material which is too tightly packed can result in
decreased combustion performance and elevated levels of carbon monoxide.

   .

Top Logs:

1.  LEFT & RIGHT TOP LOGS:  Place L E F T  and 

RIGHT TOP LOGS over Left and Right Pins on 
REAR LOG (C7) or the two FRONT LOGS 
(DFC7)
. Position as shown

2.  CENTER LOG:  Using the log locator hole and pin, 

place the CENTER LOG onto the CENTER PIN  of

REAR LOG (C7) or on the two FRONT LOG  

pins (DFC7).

WARNING: Failure to position parts in
accordance with these diagrams or failure to
use only parts specifically approved with this
heater may result in property damage or
personal injury.

Volcanic Ash Placement:  

Place VOLCANIC ASH

only on the firebox floor.  NEVER PLACE VOLCANIC

Center Log

Left Top Log

Right Top Log

"Char Effect"

Pins

"Char Effect"

Pilot

Burner

Pilot

Burner

Pins

Pins

C 7

D F C 7

 ASH (or any material other than the EMBER MATERIAL provided) ON TOP OF BURNER!

LIGHTING and OPERATION

Control Locations and Description

Manual Models (C7-M or DFC7-M)

Valve Knob (Manual Control):  Pilot Lighting,
Burner Selection (NORMAL-20,000 Btu or BOOST-
30000 Btu). (Figures 5 and 6).

Switch Models (C7-S or DFC7-S)

Primary Gas Valve Control Knob (Switch
Models):
  Pilot Lighting and Valve gas output
adjustment from OFF to FULL. See Figure 8.

3 Way Selector Switch:  Mode selections:

SWITCH ON, OFF or REMOTE ACCESS ON.  Fig 7.
All Models

Piezo Ignitor Button:  Pilot Flame Ignition.

Figure 5

3 WAY SELECTOR SWITCH

(Switch Models Only)

PIEZO IGNITER  

BUTTON

PRIMARY GAS VALVE

CONTROL KNOB

(Switch Models Only)

VALVE KNOB (Manual Model): Two settings-
Normal (20,000 Bu) or Boost (33000 Btu).

7

Summary of Contents for CHILLBUSTER Evening Embers 7 Series

Page 1: ...lace or in a listed ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs Do not use this CHILLBUSTER as a Vent Free Heater in sleeping quarters bathrooms or recreational vehicles WARNING If the information in this manual is not followed exactly a fire or explosion...

Page 2: ...es instructions stating it has not been tested or should not be used with unvented gas logs WARNING Any change to this heater or its controls can be dangerous Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpet...

Page 3: ...able vapors and liquids Provide adequate clearances for servicing and proper operation 3 Any outside air ducts and or ash dumps in the fireplace shall be permanently closed at time of installation WARNING Do not use a blower insert heat exchanger insert or other accessory not approved for use with this heater WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter...

Page 4: ...e Btu Hr against Actual Btu hr Used Maximum Supportable Btu Hr 60 160 Btu Hr Actual Btu Hr Used 72 000 Btu Hr Excess Btu Hr 11 840 Btu Hr If Actual Btu Hr Used is greater than Max Supportable Btu Hr then space is CONFINED If the Actual Btu Hr Used is less than Maximum Supportable Btu Hr then space is UNCONFINED In the example because the Actual Btu Hr Used exceeds the Maximum Supportable Btu hr th...

Page 5: ... floors between wall panels at penetrations for plumbing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may give off carbon monoxide an odorless colorless poisonous gas Some people pregnant women persons with heart or lung disease anemia or under the influence of alcohol and persons at high altitudes are m...

Page 6: ...IMNEY FLUE DAMPER OPEN Operate as a VENTED Heater See Page 3 ALL APPLICATIONS VENTED and VENT FREE OPERATION Installing Chillbuster 5 Burner Unit Into Fireplace FRONT REAR C L Gas Connect Rear Log With Rear Log on grate place grate control assembly inside firebox or approved enclosure Center left to right with the back portion of the grate assembly as far to the rear of the firebox as possible Rem...

Page 7: ...ion as shown 2 CENTER LOG Using the log locator hole and pin place the CENTER LOG onto the CENTER PIN of REAR LOG C7 or on the two FRONT LOG pins DFC7 WARNING Failure to position parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury Volcanic Ash Placement Place VOLCANIC ASH only on the firebox fl...

Page 8: ... until all air is bled and gas flows to pilot 6 Press Piezo Ignitor Button Figure 3 to light pilot Continue to hold in Primary Gas Valve Control Knob until the Pilot flame remains lit when knob is released approx 60 to 90 seconds If Pilot does not remain lit repeat steps 1 through 5 and allow additional time after Figure 8 ON POSITION v OFF POSITION v PILOT POSITION PILOT v PILOT ADJUST COVER CAP ...

Page 9: ...N Once pilot lights continue to hold in Operating Dial until the Pilot flame remains lit when knob is released approximately 60 to 90 seconds If Pilot does not remain lit repeat steps 1 through 5 and allow more time after Pilot Lighting before releasing knob Figure 9 6 Turn Operating Dial to ON Ignition Interlock The Ignition Interlock device prevents the re establishment of gas flow following a l...

Page 10: ...d of debris Use compressed air or a soft bristle brush to clear pilot and burner s air intakes Air shutters should not be altered from factory settings WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting or property damage Obstructed Pilot Air Intake Ports result in an improper gas air mixture and a weak pilot flame Weak pilot flame is the NUMBER 1 SERVICE...

Page 11: ... 2 1 4 5 C7 LOGS 12a DFC7 LOGS 2a 1a 5a 2a 40 41 1 C7 Center Log C 15 5 C7 Front Log 10 ODS Pilot N or LP 23 Manual Gas Valve 1a DFC7 Center Log U12a H21 18 Model MV or Standard 24 Valve Knob 2 C7 Left Top Log H22 24 Model 11 1 4 Pilot Supply Tubing 25 Push Button Piezo Ignitor C 13 18 or 24 Models H23 30 Model 12 C7 Grate C7or DFC7 S Switch C 10 30 Model 5a DFC7 Front Logs Two 12a DFC7 Grate 30 M...

Page 12: ...y as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitat...

Page 13: ...CHANGES next Consolidate C7 and DFC7 page 1 standard update z21 11 2a 2001 DUE 4 03 standard update z21 11 2b 2002 DUE 12 03 Title change Customer Responsibilities And Annual Maintenance page 10 13 ...

Reviews: