background image

TWO YEAR CONSUMER PRODUCT WARRANTY

The  following warranty has been drafted to comply with the MAGNUSON-MOSS WARRANTY ACT applicable to
products manufactured after July 4, 1975. It replaces and supersedes any warranty in this package or in any printed
literature.

LIMITED WARRANTY:

RASMUSSEN IRON WORKS INC, 12028 E.
Philadelphia Street, Whittier California, U.S.A.., Warrants
this Gas Log Set and accessories against defects in
materials and workmanship, and suitable for a particular
purpose, for a period of:

(1) LOG CASTING - All logs are guaranteed against
burnout in the original installation for two years from date
of initial purchase.

(2) BURNERS - 2 years from date of initial purchase.

(3) SAFETY CONTROLS - 2 years from date of initial
purchase.

THIS WARRANTY IS FOR THE BENEFIT O F
THE ORIGINAL PURCHASER.

WARRANTY ADJUSTMENT:

(1) RASMUSSEN agrees to repair or furnish a
replacement for, but not remove or install any product or
component which proves defective within the above
warranty and appropriate time periods stated.

(2) BUYER shall notify RASMUSSEN of any defect
within this warranty no later than thirty (30) days after a
defect is discovered.

(3) No product will be accepted for return or replacement
without written authorization of RASMUSSEN. Before
returning merchandise, write to RASMUSSEN giving full
details of the complaint and a copy of sales receipt or
other evidence of purchase date. Merchandise returned
without proof of purchase date will be serviced out-of
warranty at our prevailing service and parts rates. If
merchandise was damaged in transit, file claim
immediately with the carrier. Products returned must be
addressed as follows:

RASMUSSEN IRON WORKS INC

1 2 0 2 8   E .   P H I L A D E L P H I A   S T R E E T

WHITTIER CALIFORNIA 90601

Shipping charges must be pre-paid by the buyer.
REPAIR OR REPLACEMENT UNDER THIS
WARRANTY WILL BE SHIPPED FREIGHT
C O L L E C T .

EXCLUSIONS FROM WARRANTY:

(1) The foregoing warranty is limited solely as set forth
herein and applies only for the periods designated
above.

(2) RASMUSSEN shall not be liable for any loss,
damage, incidental or consequential damages of any
kind, whether based upon warranty, contract, or
negligence, arising in connection with the sale, use, or
repair of the product. Some states do not allow the
exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not
apply  to you.

(3) The maximum liability of RASMUSSEN in connection
with this limited warranty shall not in any case exceed the
contract price paid for the product claimed to be
defective or unsuitable.

(4) This warranty does not extend to any product
manufactured by RASMUSSEN which has been
subjected to misuse, neglect, accident, improper
installation, or use in violation of instructions furnished
by RASMUSSEN. Do not remove Rating Plate/Warning
Tags. These tags serve you and any future user as an
integral safety and identification component of the
CHILLBUSTER gas log heater.  Removing these tags
voids the warranty.

(5) This warranty does not extend to or apply to any unit
which has been repaired or altered at any place other
than RASMUSSEN IRON WORKS INC factory, or by
persons not expressly approved by RASMUSSEN.

(6) Components manufactured by any supplier other
than RASMUSSEN shall bear only that warranty made by
the manufacturer of that product.

(7) Freight damage, cracking from thermal shock, and
color changes occur from causes beyond
manufacturer's control and are not covered by any
warranty.

THIS WARRANTY GIVES YOU SPECIFIC LEGAL
RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS
WHICH VARY FROM STATE TO STATE.

RASMUSSEN IRON WORKS, INC. shall be held
harmless from any and all claims by the buyer as a result
of injury or damage to an ultimate user or other person
caused by the product sold herein by the seller to the
buyer, whether the injury or damage results from the
assembly, installation, operation, shipment, storage or
manufacture of this product. RASMUSSEN IRON
WORKS, INC. makes no warranties, expressed or
implied, other than those expressly stated herein.

CB WARRRANTY 2-03

12

Summary of Contents for CHILLBUSTER Evening Embers 7 Series

Page 1: ...lace or in a listed ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs Do not use this CHILLBUSTER as a Vent Free Heater in sleeping quarters bathrooms or recreational vehicles WARNING If the information in this manual is not followed exactly a fire or explosion...

Page 2: ...es instructions stating it has not been tested or should not be used with unvented gas logs WARNING Any change to this heater or its controls can be dangerous Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpet...

Page 3: ...able vapors and liquids Provide adequate clearances for servicing and proper operation 3 Any outside air ducts and or ash dumps in the fireplace shall be permanently closed at time of installation WARNING Do not use a blower insert heat exchanger insert or other accessory not approved for use with this heater WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter...

Page 4: ...e Btu Hr against Actual Btu hr Used Maximum Supportable Btu Hr 60 160 Btu Hr Actual Btu Hr Used 72 000 Btu Hr Excess Btu Hr 11 840 Btu Hr If Actual Btu Hr Used is greater than Max Supportable Btu Hr then space is CONFINED If the Actual Btu Hr Used is less than Maximum Supportable Btu Hr then space is UNCONFINED In the example because the Actual Btu Hr Used exceeds the Maximum Supportable Btu hr th...

Page 5: ... floors between wall panels at penetrations for plumbing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may give off carbon monoxide an odorless colorless poisonous gas Some people pregnant women persons with heart or lung disease anemia or under the influence of alcohol and persons at high altitudes are m...

Page 6: ...IMNEY FLUE DAMPER OPEN Operate as a VENTED Heater See Page 3 ALL APPLICATIONS VENTED and VENT FREE OPERATION Installing Chillbuster 5 Burner Unit Into Fireplace FRONT REAR C L Gas Connect Rear Log With Rear Log on grate place grate control assembly inside firebox or approved enclosure Center left to right with the back portion of the grate assembly as far to the rear of the firebox as possible Rem...

Page 7: ...ion as shown 2 CENTER LOG Using the log locator hole and pin place the CENTER LOG onto the CENTER PIN of REAR LOG C7 or on the two FRONT LOG pins DFC7 WARNING Failure to position parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury Volcanic Ash Placement Place VOLCANIC ASH only on the firebox fl...

Page 8: ... until all air is bled and gas flows to pilot 6 Press Piezo Ignitor Button Figure 3 to light pilot Continue to hold in Primary Gas Valve Control Knob until the Pilot flame remains lit when knob is released approx 60 to 90 seconds If Pilot does not remain lit repeat steps 1 through 5 and allow additional time after Figure 8 ON POSITION v OFF POSITION v PILOT POSITION PILOT v PILOT ADJUST COVER CAP ...

Page 9: ...N Once pilot lights continue to hold in Operating Dial until the Pilot flame remains lit when knob is released approximately 60 to 90 seconds If Pilot does not remain lit repeat steps 1 through 5 and allow more time after Pilot Lighting before releasing knob Figure 9 6 Turn Operating Dial to ON Ignition Interlock The Ignition Interlock device prevents the re establishment of gas flow following a l...

Page 10: ...d of debris Use compressed air or a soft bristle brush to clear pilot and burner s air intakes Air shutters should not be altered from factory settings WARNING Failure to keep the primary air opening s of the burner s clean may result in sooting or property damage Obstructed Pilot Air Intake Ports result in an improper gas air mixture and a weak pilot flame Weak pilot flame is the NUMBER 1 SERVICE...

Page 11: ... 2 1 4 5 C7 LOGS 12a DFC7 LOGS 2a 1a 5a 2a 40 41 1 C7 Center Log C 15 5 C7 Front Log 10 ODS Pilot N or LP 23 Manual Gas Valve 1a DFC7 Center Log U12a H21 18 Model MV or Standard 24 Valve Knob 2 C7 Left Top Log H22 24 Model 11 1 4 Pilot Supply Tubing 25 Push Button Piezo Ignitor C 13 18 or 24 Models H23 30 Model 12 C7 Grate C7or DFC7 S Switch C 10 30 Model 5a DFC7 Front Logs Two 12a DFC7 Grate 30 M...

Page 12: ...y as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitat...

Page 13: ...CHANGES next Consolidate C7 and DFC7 page 1 standard update z21 11 2a 2001 DUE 4 03 standard update z21 11 2b 2002 DUE 12 03 Title change Customer Responsibilities And Annual Maintenance page 10 13 ...

Reviews: