background image

Rasha Professional A/S 375 W Esplanade Ave. San Jacinto, CA 92583 

951-654-3585

rashaprofessional .com 

|

 [email protected]  Rev. 101615

6

1

2

3

1

2

3

DMX +

COMMON

Figure 4

DMX -

DMX512 OUT

3-PIN XLR

DMX512 IN

3-PIN XLR

XLR Male Socket

XLR Pin Configuration

1 Ground

1 Ground

2 Cold

2 Cold

Pin 1 = Ground

Pin 2 = Data Compliment (negative)

Pin 2 = Data True (Positve)

3 Hot

3 Hot

XLR Female Socket

Figure 3

Notice: 

Be sure to follow figures two and three when making your own cables. 

Do not use the ground lug on the XLR connector. Do not connect the cable’s 

shield conductor to the ground lug or allow the shield conductor to come in 

contact with the XLR’s outer casing. Grounding the shield could cause a short 

circuit and erratic behavior.

Special Note: Line Termination.

 When longer runs of cable are used, you 

may need to use a terminator on the last unit to avoid erratic behavior. A 

terminator is a 110-120 ohm 1/4 watt resistor which is connected between 

pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is 

inserted in the female XLR connector of the last unit in your daisy chain to 

terminate the line. Using a cable terminator (Rasha part number R-DMX/T) will 

decrease the possibilities of erratic behavior 

5-Pin XLR DMX Connectors.

 Some manufactures use 5-pin DMX-512 

data cables for DATA transmission in place of 3-pin. 5-pin DMX fixtures may 

be implemented in a 3-pin DMX line. When inserting standard 5-pin data 

cables in to a 3-pin line a cable adaptor must be used, these adaptors are 

readily available at most electric stores. The chart below details a proper cable 

conversion.

3-Pin XLR to 5-Pin XLR Conversion

Conductor

3-Pin XLR Female (Out)

5-Pin XLR Male (In)

Ground/Sheild

Pin1

Pin1

Data Compliment (- signal)

Pin 2

Pin 2

Data True (+ signal)

Pin 3

Pin 3

Not Used

Do Not Use

Not Used

Do Not Use

1

2

3

Figure 5

Termination reduces signal erros and acoids 

signal transmission problems and intreference. it 

is always advisable to connect a DMX terminal. 

(Resisantce 120 Ohm 1/4W) Between PIN 2 

(DMX-) and PIN 3 (DMX+) of the last fixture.

Set Up

Summary of Contents for HEX V12 Wireless

Page 1: ...REDUCE THE RISK OF ELECTRICAL SHOCK OR FIRE DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE CAUTION THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF DOING SO WILL...

Page 2: ...reless Every Rasha Hex V12 Wireless has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping...

Page 3: ...Rasha Professional A S 375 W Esplanade Ave San Jacinto CA 92583 951 654 3585 rashaprofessional com info rashaprofessional com Rev 101615 3 This page is left intentionally blank...

Page 4: ...p Gradually auto change To optimize the performance of this product please read these operating instructions carefully to familiarize yourself with the basic operations of this unit These instructions...

Page 5: ...ween this device and a wall Do not attempt to operate this unit if it becomes damaged This unit is intended for indoor use only use of this product outdoors voids all warranties During long periods of...

Page 6: ...r which is connected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line Using a cab...

Page 7: ...hannel DMX 12 channel DMX Set fixture to Slave Mode Set Fixture to Master Mode Receive the signal but do not transmit signal Built In auto Color change IR remote control activation 34 preset colors Sl...

Page 8: ...this mode is activated all modes will return to their default settings 1 Press the MENU button until ENTER Press and press ENTER for DMX Mode 2 Press the SET UP button until is displayed 3 Press the U...

Page 9: ...only 2 Set first light at and rest of fixtures on SL1 Mode It means first fixture will be the master fixture which send same operating command to other fixtures of the network we call those other fixt...

Page 10: ...s different DMX channel modes please select your desired mode by pressing the DMX Mode button then using the Up or Down buttons to scroll through the DMX Channel Modes Set the mode before you address...

Page 11: ...on 1 255 Amber dimmer Sharp CH5 0 No action 1 255 White 0 255 white dimmer CH6 0 No Action 1 255 UV 0 255 UV dimmer CH7 0 No Action 1 255 Strobe 12 CH Mode Channel Value Description CH1 0 No action bl...

Page 12: ...Rev 101615 12 CH7 0 8 No action blackout Preset color 8 15 Strobe from slow to fast 16 23 Pulse 24 30 Random 31 38 39 46 47 54 55 61 62 69 70 77 78 85 86 92 93 100 101 108 109 116 117 123 124 131 132...

Page 13: ...2 may be hot Also check that all cables are connected to the right connectors it does matter which way the inputs and outputs are connected Unit does not respond to sound 1 Quiet or high pitched soun...

Page 14: ...issued to purchaser by Rasha Professional A S LLC if the product is damaged because not properly maintained as set forth in the instruction manual This is not a service contract and this warranty doe...

Page 15: ...3Kgs Dimensions 20 L x6 W x 20 CM Colors RGB Amber White UV Color Mixing and single color Color 16 7 million kinds of color change DMX Channels 7 12 DMX Built In 2 4 MHZ wireless Signal receiver Cont...