![Rapid Controls TDD2 User Manual Download Page 38](http://html1.mh-extra.com/html/rapid-controls/tdd2/tdd2_user-manual_3680787038.webp)
34
$
<id>
RPo
<CR>
Write Syntax:
$
<id
>
SPo
<o><CR>
where:
id
is the node id of the TDD2
and
o
is the soft offset in units
Examples:
To read the soft offset from a TDD2 with node id 5 send:
$5RPo
<CR>
To set the soft offset to 2.335 units using a TDD2 with node id 7 send:
$7Spo2.335
<CR>
7.4.6
Direction Sense
Reads or sets the number of displayed decimal places. See section 4.1.1 for information on this
setting.
Read Syntax:
$
<id>
RPD
<CR>
Write Syntax:
$
<id
>
SPD
<d><CR>
where:
id
is the node id of the TDD2
and
d
is the direction sense, “POSITIVE” or “NEGATIVE”
Examples:
To read the direction sense from a TDD2 with unknown node id send:
$0RPD
<CR>
To set the direction sense to positive using a TDD2 with node id 1 send:
$1SPDPOS
<CR>