18
44
Set magnet offset 1 to preset 3 and magnet offset 3 to
preset 4
45
Enable peak display mode
46
Disable peak display mode
47
Toggle peak display mode
48
Clear peak reading
49
Toggle peak display mode and clear peak reading when
toggled to enable
50
Enable peak display mode and clear peak reading
51
When in gap mode, zeroes the current gap by clearing all
per-magnet offsets and setting the per-magnet offset for the
2nd magnet in the gap.
52
Disable the front panel menu, except Preset 1 may still be
changed
Table 7: Digital Input Actions
4.8
Front Panel Actions
The front panel switches can be programmed to perform actions when they are pressed (Tap) or held
for 2 seconds. These are similar to the input actions defined in 4.7. Front panel actions may be used even if
the front panel menu has been disabled.
Action Number
Action Performed
0
No Action (Input disabled)
1
Increment displayed magnet
2
Decrement displayed magnet
3
Increment gap
4
Decrement gap
5
Increment reference magnet
6
Decrement reference magnet
7
Zero the position by setting the hard offset
8
Zero the position by setting the soft offset
9
Send the current position over the RS-232/485 interface
10
Stop display updates and “hold” the current position.
11
Increment the current transducer type
12
Decrement the current transducer type
13
Increment Hard Offset by Preset 1 amount
14
Increment Hard Offset by Preset 2 amount
15
Increment Hard Offset by Preset 3 amount
16
Increment Hard Offset by Preset 4 amount
17
Increment Soft Offset by Preset 1 amount
18
Increment Soft Offset by Preset 2 amount
19
Increment Soft Offset by Preset 3 amount
20
Increment Soft Offset by Preset 4 amount
21
Change hard offset in order to “zero” position to preset 1
22
Change hard offset in order to “zero” position to preset 2
23
Change hard offset in order to “zero” position to preset 3
24
Change hard offset in order to “zero” position to preset 4
25
Change soft offset in order to “zero” position to preset 1
26
Change soft offset in order to “zero” position to preset 2
27
Change soft offset in order to “zero” position to preset 3
28
Change soft offset in order to “zero” position to preset 4
29
Set hard offset to value of Preset 1
30
Set hard offset to value of Preset 2
31
Set hard offset to value of Preset 3