AH-07-01.8
Vector AA90 Applicators - Installation
3 0
3 0
3 0
3 0
3 0
LOW VOL
LOW VOL
LOW VOL
LOW VOL
LOW VOLT
T
T
T
TAGE CABLE
AGE CABLE
AGE CABLE
AGE CABLE
AGE CABLE
Connect the low voltage cable from the control unit
to the applicator using a wrench to tighten.
Figure 11: Daisy Chained Cable
Figure 11: Daisy Chained Cable
Figure 11: Daisy Chained Cable
Figure 11: Daisy Chained Cable
Figure 11: Daisy Chained Cable
>
DO NOT
DO NOT
DO NOT
DO NOT
DO NOT overtighten the low voltage
connection at the applicator. The plastic
parts could be damaged.
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
!!!!!
With the Vector design, multiple cables may be
connected together to create the length required,
up to a maximum of 30m (100 ft.). To connect the
cables, insert the male end of one cable into the
female end of the other. Tighten both cable
connectors against each other using two (2) 16mm
(5/8") open-end wrenches.
>
The control unit power supply MUST
be located at least 3 feet outside of the
spray area. Install units in accordance
with the code requirements. (See local
and national codes.)
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
>
The electrical discharge that is available
from the charging electrode must not exceed
0.25 mJ of energy. To achieve this limit, any
flow of energy from the paint supply through
the paint line to the applicator electrode must
be prevented by grounding the paint line at
the applicator handle.
>
Verify that the applicator handle is
actually grounded before operating it! This is
done with a fully connected and operational
system, by placing one lead of an ohmmeter
to the handle and the other to the building
electrical ground (cold water pipe, building
structure, steel, etc.). This reading should
be essentially zero.
>
If a greater reading is obtained, check
that the control unit is grounded. (See the
control unit manual for "Grounding Proce-
dure".)
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
TYPICAL AA90 CLASSIC
TYPICAL AA90 CLASSIC
TYPICAL AA90 CLASSIC
TYPICAL AA90 CLASSIC
TYPICAL AA90 CLASSIC
APPLICA
APPLICA
APPLICA
APPLICA
APPLICAT
T
T
T
TOR
OR
OR
OR
OR
INST
INST
INST
INST
INSTALLA
ALLA
ALLA
ALLA
ALLATION
TION
TION
TION
TION
Connect the low voltage cable to the control unit
low voltage socket. Gently hand tighten the cable
retaining nut.
Connect the outlet from a regulator supply switch
with air hose to the applicator using a wrench.
(The cascade unit uses reed switch triggering)
The control unit may be connected through conduit
with an explosion-proof switch on or near the
spray booth where it will be convenient to the
operator, or may be connected with a power cord
depending upon application requirement.