Bi-Yearly
• Check air hose resistance. If resistance is greater
than 0.5 MegOhm
the hose should be replaced.
Air Cap Removal
1. Remove retaining ring and air cap.
Daily (or at start of each shift)
• Verify that ALL solvent safety containers are
grounded!
• Check within 6m (20-ft.) of the point of operation (of
the applicator) and remove or ground ALL loose or
ungrounded objects.
• Inspect work holders for accumulated coating
materials (and remove such accumulations).
• Check that atomizer assembly is clean and
undamaged.
• Straighten the applicator electrode if necessary.
• Clean the fluid filter, if used.
• On quick disconnect units check qd function. If
worn replace hose assembly.
0.5 MegOhm max
W A R N I N G
!
It is the end users responsibility to insure the
0.5 MegOhm
to ground condition is met.
NOTE
Standard electrode is "snap back" spray
wire electrode.