Motor Removal
1. Remove light pipe.
2. Remove screw and retainer.
3.
Remove motor assembly by pulling out on 3
arms, pull motor out.
4. Remove porting block.
5. Remove fluid valve cartridge O-ring.
NOTE
Block must be pulled out with fingers rocking
the part side to side while pulling.
NOTE
Only remove fluid valve cartridge if parts are
being changed.
6. Push on edges to remove fluid valve cartridge.
AH-17-04-R0.0 (11/2017)