-8-
WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.
-9-
WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.
BLACK / NEGRO
BLACK / NEGRO
IGNITOR / ALLUMEUR
BLACK / NEGRO
GREEN / VERDE
WHITE / BLANCO
WHITE / BLANCO
WHITE / BLANCO
BLUE / AZULE
BLUE / AZULE
BLUE / AZULE
BLUE / AZULE
SPARK MODULE /
MODULE D'ÉTINCELLE
EARTH (SHELL) /
TERRE
(COQUILLE)
POWERCORD /
CABLE
ÉLECTRICO
FUSE: 250V/2A
THERMAL SWITCH /
INTERRUPTEUR THERMIQUE
TH
ER
MO
CO
UP
LE
EARTH / TERRE
CO
NT
RO
L V
ALVE /
SO
UP
AP
E DE
CO
MM
AND
E
YELLOW / JAUNE
YELLOW / JAUNE
MOTOR /
MOTEUR
CONDENSER /
CONDENSEUR
WIRING DIAGRAM
SIZE AND CAPACITY OF PROPANE CYLINDERS REQUIRED
45,000 - 60,000 BTU/h
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
60
40
20
20# (9kg) CYLINDER
40# (18kg) C
YLINDER
0
-20
(16)
(4.4)
(-6.7)
(-18)
(-29)
DUR
ATION OF OPER
ATION ON M
A
X - HOURS
AIR TEMPERATURE - °F (°C)
125,000 BTU/h
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
60
40
20
100# (45.4KG)
100# (45.4KG)
100# (45.4KG)
3 cylinders
2 cylinders
1 cylinder
0
-20
Use liquid withdrawal
and a vaporizer
(16)
(4.4)
(-6.7)
(-18)
(-29)
M
A
XIMUM OPER
ATING
TIME - HOURS
AIR TEMPERATURE - °F (°C)
40
38
36
34
32
155,000 BTU/h
60
40
20
0
-20
Use liquid withdrawal
and a vaporizer
M
A
XIMUM OPER
ATING
TIME - HOURS
AIR TEMPERATURE - °F (°C)
Fuel Cylinder
Capacity: 100#
-10
10
30
50
(16)
(4.4)
(-7)
(-18)
(-29)
(-23)
(-12)
(-1)
(10)
0
22
24
26
28
30
20
32
34
36
38
18
16
2
14
12
10
8
6
4
SIZE AND CAPACITY OF PROPANE CYLINDERS REQUIRED
The charts below show the approximate size of the cylinder required for these heaters. To use the chart:
1.
Select the lowest air temperature expected (at the bottom of the chart).
2.
Move straight up to time of operation desired (left side of chart).
3.
Read the cylinder size required.
-8-
WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.
-9-
WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.
5
4
3
6
2
1
In order to maintain warranty, components must be replaced using original manufacturers parts purchased through your
dealer or directly from PowerFast Products Group (423) 837-5155. Use of third party components will void the warranty.
KEY
DESCRIPTION
MODEL
PART NO
1
Motor Assembly
R45LP, R60LP
80835
R125LP, R160LP
80836
2
Fan
R45LP, R60LP
893130
R125LP, R160LP
893131
3
Handle
893127
4
Multi Bracket
Assembly
R45LP, R60LP,
R125LP
893128
R160LP
893129
5
Spark Module
80837
6
Regulator
Assembly
R45LP, R60LP
81323
R125LP, R160LP
81324
PARTS DIAGRAM