background image

-4-

WARNING: Never leave the heater unattended while operating. 

Disconnect the heater from its power source when not in use.

-5-

WARNING: Never leave the heater unattended while operating. 

Disconnect the heater from its power source when not in use.

 WARNING: RISK OF CARBON MONOXIDE POISONING

 

Use this heater only in well ventilated areas! Provide at 

least a three square feet (2,800 sq cm) opening of outside 

air for every 45,000 BTU/Hr. of heater rating.

 

People with breathing problems should consult a physician 

before using the heater.

 

Early signs of carbon monoxide poisoning resemble flu-like 

symptoms such as headaches, dizziness, and/or nausea. 

If you have these symptoms, your heater may not be 

working properly.

 

Get fresh air at once! Have the heater serviced.

 

Some people are more affected by carbon monoxide than 

others. These include pregnant women, those with heart 

or lung problems, anemia, those under the influence of 

alcohol, or at high altitudes.

 

Never use this heater in living or sleeping areas.

 WARNING: RISK OF ELECTRIC SHOCK

 

EQUIPMENT MUST BE GROUNDED.

 

Use only the power (voltage) specified for this heater. 

Refer to the model plate on the heater.

 

Use only a three-prong grounded outlet and extension 

cord.

 

ALWAYS install heater so that it is not directly exposed to 

water spray, rain, dripping water, or wind.

 

ALWAYS disconnect the heater from its power source 

when not in use.

 DANGER:

An odorant has been added to LPG (propane) to give that gas a distinctive smell. That smell makes it easier to detect a leak. 

Some people cannot smell the odorant and must rely on electronic leak sensors.
If you detect a leak,

 

DO NOT enter the premises if you notice a strong gas 

odor.

 

EXTINGUISH all flames and heat sources.

 

DO NOT smoke, or create a spark or a flame.

 

DO NOT turn on any electrical switches, appliances or 

lights as an electrical charge could create a spark.

 

DO NOT operate your garage door.

 

DO NOT use your telephone.

 

CLOSE all propane (LP) gas tanks.

 

VACATE the area until declared safe by firefighters.

 

KEEP OUT of low areas; Propane is lighter than air and 

settles in low lying areas.

OPERATING PRECAUTIONS

This is a propane, direct-fired, propane heater. This heater was designed and certified as a construction heater in accordance with 

ANSI Z83.7-2017 / CSA 2.14-2017. The intended use of this heater is the temporary heating of buildings under construction, 

alteration or repair or for spot heating when the products of combustion are discharged outdoors. Check with your local fire safety 

authority if you have any questions about the application of this heater. Other standards govern the use of fuel gases and heat 

producing products in specific applications. Your local authority can advise you about these.
This is an unvented portable direct-fired propane heater and all of the products of combustion are released into the area being 

heated. This heater operates at close to 100 percent combustion efficiency but still produces carbon monoxide (CO) a deadly gas. 

Carbon Monoxide can build up and failure to provide adequate ventilation could result in poisoning and death.
Know the signs of CO and CO

2

 poisoning:

 

Headaches, stinging eyes

 

Dizziness, disorientation

 

Difficulty breathing, feeling of being suffocated

Monitor levels of CO when operating this heater. DO NOT USE IN UNVENTILATED AREAS.

-4-

WARNING: Never leave the heater unattended while operating. 

Disconnect the heater from its power source when not in use.

-5-

WARNING: Never leave the heater unattended while operating. 

Disconnect the heater from its power source when not in use.

MINIMUM CLEARANCE (FROM NORMAL 

COMBUSTIBLE MATERIAL)

Clearance

ft

m

From floor

0

0

From outlet

6

1.8

From sides

2

0.6

From top

3

0.9

Locate 10ft from canvas or plastic tarpaulins or similar 

coverings and secure them to prevent flapping or 

movement due to wind action

 WARNING:

1. 

Inspect the heater before each use and at least annually 

by a qualified service person. DO NOT operate a damaged 

heater.

2. 

Inspect the hose assembly prior to each use of the heater. 

If there is evidence there is excessive abrasion or wear, 

or  the  hose  is  cut,  replace  the  hose  prior  to  operating 

the  heater.  Use  only  the  hose  specified  by  PowerFast 

Products.

3. 

The  hose  assembly  shall  be  protected  from  traffic, 

building  materials  and  contact  with  hot  surfaces  both 

during use and while in storage.

4. 

DO NOT modify the heater or operate a heater which has 

been modified from its original condition.

5. 

Use only propane gas.

6. 

Use  only  VAPOR  WITHDRAWAL  propane  supply.  If 

there is any question about vapor withdrawal, ask your 

propane dealer.

7. 

Mount  the  propane  cylinders  vertically  (shutoff  valve 

up). Secure them from falling or being knocked over and 

protect them from damage.

8. 

Locate propane containers at least 6 ft. (1.83 m) in the 

U.S. and 10 ft. (3 m) in Canada from any propane cylinder.

9. 

DO NOT direct the heater discharge toward any propane 

cylinder located within 20 ft. (6 m).

10. 

KEEP  heater  clear  and  free  of  combustible  materials, 

gasoline and other flammable vapors and liquids.

11. 

KEEP 

CHILDREN, 

CLOTHING, 

PETS 

AND 

COMBUSTIBLES AWAY FROM HEATER.

12. 

Operate only on a stable, level surface.

13. 

Do  not  use  with  duct  work.  Do  not  restrict  inlet  (air 

intake) or outlet (discharge opening).

14. 

Do not move, handle or service this heater while hot or 

burning.

15. 

Do not adjust the heater combustion tube elevation while 

heater is running or hot. Adjustments to elevation should 

only be made after the heater has cooled to the touch.

16. 

Store the heater indoors when not in use.

17. 

Disconnect the hose assembly from the propane cylinder 

when the heater is not in use. Store the propane cylinder 

in  accordance  with  the  Standard  for  the  Storage  and 

Handling  of  Liquefied  Petroleum  Gases,NFPA  58  and 

Natural Gas and Propane Installation Code, CSA B149.1.

Summary of Contents for R45LP

Page 1: ...ane Installation Code CSA B149 1 ANSIZ83 7 2017 CSA 2 14 2017 R45LP R60LP R125LP R160LP READ AND SAVE THESE INSTRUCTIONS Carefully read and understand these instructions before assembling operating or...

Page 2: ...CTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PARTICLES OR UNKNOWN CHEMICALS WARNING NOT FOR...

Page 3: ...art 1926 154 ANSI A10 10 Safety Requirements for Temporary and Portable Space Heating Devices and Equipment used in the Construction Industry or the Natural Gas and Propane Installation Codes CSA B149...

Page 4: ...or create a spark or a flame DO NOT turn on any electrical switches appliances or lights as an electrical charge could create a spark DO NOT operate your garage door DO NOT use your telephone CLOSE a...

Page 5: ...has been modified from its original condition 5 Use only propane gas 6 Use only VAPOR WITHDRAWAL propane supply If there is any question about vapor withdrawal ask your propane dealer 7 Mount the pro...

Page 6: ...ter 3 DO NOT CONNECT THE POWER CORD TO AN OUTLET UNTIL YOU HAVE FINISHED THE PREPARATION 4 Connect the POL fitting of hose and regulator assembly to the propane cylinder by rotating the POL nut counte...

Page 7: ...adjusting the heater RESTARTING AFTER SHUTDOWN 1 Securely close the gas valve at the propane cylinder 2 Disconnect the heater from its power source 3 Restart following the Lighting Instructions proce...

Page 8: ...F C 125 000 BTU h 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 60 40 20 100 45 4KG 100 45 4KG 100 45 4KG 3 cylinders 2 cylinders 1 cylinder 0 20 Use liquid withdrawal and a vaporizer 16 4 4 6 7 18 29 MA...

Page 9: ...1 In order to maintain warranty components must be replaced using original manufacturers parts purchased through your dealer or directly from PowerFast Products Group 423 837 5155 Use of third party...

Page 10: ...easonable proof of the date of purchase from an authorized retailer or distributor This Limited Warranty does not cover any operational failures or difficulties due to normal use and wear and tear acc...

Page 11: ...oprement install entretenu et doit fonctionner selon les instructions ci jointes De plus PowerFast requiert une preuve raisonnable de la date d achat effectu e aupr s du fournisseur ou du distributeur...

Page 12: ...Product Group 423 837 5155 L utilisation de composantes provenant de tiers annulera la garantie SCH MA DES PI CES R F RENCE DESCRIPTION MOD LE NO DE PI CE 1 Assemblage du moteur PF45G PF60G 80835 PF12...

Page 13: ...125 000 BTU heure 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 60 40 20 100 45 4KG 100 45 4KG 100 45 4KG 3 bouteilles 2 bouteilles 1 bouteille 0 20 Utilisez l extraction de liquide et un vaporisateur 1...

Page 14: ...source d nergie 3 Red marrez en suivant la proc dure Instructions d allumage ENTREPOSAGE ET ENTRETIEN 1 Le radiateur devrait tre inspect avant chaque utilisation et au moins une fois par ann e par un...

Page 15: ...es manquantes veuillez communiquer imm diatement avec PowerFast Product Group au 423 837 5155 pour demander de l aide 2 Inspectez l assemblage du tuyau avant d utiliser le radiateur Si vous d tectez d...

Page 16: ...de propane la verticale la vanne de fermeture vers le haut Fixez les afin qu elles ne tombent pas et qu elles ne soient pas renvers es et prot gez les des dommages 8 Placez les contenants de propage...

Page 17: ...sentir la substance odorante et doivent se fier des d tecteurs de fuites lectroniques Si vous d tectez une fuite NE P N TREZ PAS dans les locaux si vous d tectez une forte odeur de gaz TEIGNEZ toutes...

Page 18: ...Veuillez suivre p riodiquement les niveaux de CO CO 2 et NO 2 existant sur le site de construction au moins au d but du quart et toutes les 4 heures par la suite Veuillez fournir une ventilation et ci...

Page 19: ...S MAT RIAUX DE CONSTRUCTION LE PAPIER OU LE CARTON UNE DISTANCE S CURITAIRE DE CE RADIATEUR TEL QUE RECOMMAND DANS LES INSTRUCTIONS N UTILISEZ JAMAIS CE RADIATEUR DANS DES ESPACES CONTENANT OU POUVANT...

Page 20: ...AUTORIT DE S CURIT INCENDIE LOCALE SI VOUS AVEZ DES QUESTIONS SUR LES APPLICATIONS Ce r chauffeur doit tre install et utilis conform ment la r glementation des autorit s locales comp tentes ou en l ab...

Reviews: