27
Technical Data
This cooker is designed for use on either:
Natural gas (Cat I2H) at 20mbar or LP GAS (Cat I3+) Butane 29mbar/Propane 37mbar.
Note:
The natural gas and LP gas versions of these cookers are different models and CANNOT be converted from one gas
family to the other
Installer:
Please leave these instructions with the user.
Data Badge Location:
Lower right-hand cooker upright (remove storage drawer)
Country of Destination:
GB
Gas
Electric
Natural Gas
20mbar
220-240V 50Hz
Butane
29mbar
Propane
37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height
minimum 893mm
maximum 920mm
Overall width
1100mm see 'Positioning of Cooker'
Overall depth
648mm
Space for fixing
See 'Positioning of Cooker'
Minimum space above hotplate
650mm
Connections
Gas
Electric
Rp ½ at rear right-hand side
220-240V 50Hz
Ratings
Natural Gas
L.P. Gas
Hotplate
Injector
Injector
Wok burner
3.5kW
internal 80
3.5kW (246g/h)
internal 54
external 129
external 77
Large Burner
3.0kW
134
3.0kW (210g/h)
87
Medium Burners
1.7kW
109
1.7kW 119g/h)
68
Small Burner
1.0kW
75
1.0kW (70g/h)
51
Ovens
3.2kW
237
2.9kW (224g/h)
85
Grill
2.73kW
190
2.73kW (192g/h)
85
Gas burner inputs based on Gross Calorific Value