3.4 - AIR REGULATOR / FILTER 

 

Air regulator/filter adjusts the air pressure to the plasma torch.  It also acts as a filter and removes moisture 
from compressed air.   The air regulator attaches to the rear of the unit.   From the compressor the air is 
connected to the regulator.  From the regulator a tube will connect to the GAS IN nozzle in the rear of the 
unit which supplies the air to the plasma torch.  The L shaped QUICK-RELEASE Nozzle also connects to 
the middle position of the air regulator.   The orange tube connects to this QUICK RELEASE ‘L’ NOZZLE.  
The orange tube is connected to the pressure gauge located in the front panel.    The adjustment knob on 
top of the regulator adjusts the air pressure.  Lift and turn this knob to adjust the air pressure.     
 
Moisture from the compressed air is filtered and collected in the glass bowl and can be drained by pulling 
the WATER DRAIN RELEASE.    

 

CAUTION 

 

TURN THE UNIT OFF BEFORE DRAINING THE WATER AS THE DRAINED WATER MAY GET SUCKED 
INSIDE THE UNIT BY THE TURNING FAN. 

 

 

IMPORTANT

 

 

WHEN INSTALLING REGULATOR FITTINGS FOLLOW THE ARROW ON THE REGULATOR FOR AIR 
FLOW DIRECTION. FAILURE TO INSTALL FITTINGS IN PROPER DIRECTION WILL SUBSTANTIALLY 
AFFECT PLASMA CUTTER PERFORMANCE.  

 

 
 
 
 
 
 
 
 
 
 
 

 
 

Summary of Contents for CUT 50 DY Series

Page 1: ...sma cutters Rev 10 0993 Copyright Ramsond Corporation All rights protected Unauthorized reproduction prohibited INSTRUCTION MANUAL Digital Inverter Air Plasma Cutter MODELS CUT 50 70 DY Series Serial...

Page 2: ...ead the safety precautions They will help you protect yourself against potential hazards on the worksite We ve made installation and operation quick and easy With Ramsond you can count on years of rel...

Page 3: ...WARNING 3 1 5 PRINCIPAL SAFETY STANDARDS 4 1 6 EMF INFORMATION 4 SECTION 2 BASIC PRINCIPALS AND TERMINOLOGY OF PLASMA CUTTING 5 SECTION 3 GETTING STARTED 6 3 1 WIRING 6 3 2 FRONT PANEL 7 3 3 BACK PAN...

Page 4: ...Instruction Manual Ramsond CUT series plasma cutters Rev 10 0993 Copyright Ramsond Corporation All rights protected Unauthorized reproduction prohibited Page 1...

Page 5: ...Instruction Manual Ramsond CUT series plasma cutters Rev 10 0993 Copyright Ramsond Corporation All rights protected Unauthorized reproduction prohibited Page 2...

Page 6: ...Instruction Manual Ramsond CUT series plasma cutters Rev 10 0993 Copyright Ramsond Corporation All rights protected Unauthorized reproduction prohibited Page 3...

Page 7: ...Instruction Manual Ramsond CUT series plasma cutters Rev 10 0993 Copyright Ramsond Corporation All rights protected Unauthorized reproduction prohibited Page 4...

Page 8: ...s supplied to the electrode and the plasma stays in contact with the metal that is being cut The cutter nozzle has a second set of channels These channels release a constant flow of shielding gas arou...

Page 9: ...ng the power between 110 and 220 V as the machine automatically detects the voltage CAUTION Due to the current draw Amp this unit should NOT be connected to the standard household 110V outlet A 30 Amp...

Page 10: ...splay turn the Amperage A knob to maximum position and then calibrate the display to the maximum current e g 50A for CUT50 AIR CONNECTION The air hose of the plasma torch attaches to this connection B...

Page 11: ...y installed into quick disconnect fitting PRESSURE REGULATOR Adjust pressure to desired levels NOTE THE ARROW DIRECTION ON THE REGULATOR TO ENSURE PROPER INSTALLATION See Following Page AIR LINE IN En...

Page 12: ...SE Nozzle also connects to the middle position of the air regulator The orange tube connects to this QUICK RELEASE L NOZZLE The orange tube is connected to the pressure gauge located in the front pane...

Page 13: ...Instruction Manual Ramsond CUT series plasma cutters Rev 10 0993 Copyright Ramsond Corporation All rights protected Unauthorized reproduction prohibited Page 10 3 5 GENERAL SET UP DIAGRAM...

Page 14: ...ODY HANDLE Always inspect unit before use If any defects are present do not use Call technical support CONSUMABLES Includes cup tip swirl ring and reversible electrode Each unit comes with 5 cups 5 sw...

Page 15: ...orporation All rights protected Unauthorized reproduction prohibited Page 12 3 7 GROUND CLAMP GROUND CLAMP Ensure ground clamp is firmly installed on work piece Install clamp on a work piece that is N...

Page 16: ...reproduction prohibited Page 13 3 8 DUTY CYCLE The unit is installed with internal duty cycle overload protection In the event that the unit is overloaded or overheats let unit cool off Continuous ove...

Page 17: ...move the torch in the desired direction keeping the torch tip slightly angled Maintain contact with the work piece Move the torch just fast enough to maintain spark concentration under the work piece...

Page 18: ...ENEVER SERVICE OR INSPECTION OF MACHINE IS CONDUCTED DISCONNECT UNIT FROM POWER SOURCE AND LET UNIT COOL DOWN AFTER EACH USE CLEAN AND INSPECT TORCH CUP TIP SWIRL RING AND REVERSIBLE ELECTRODE MAKE SU...

Page 19: ...on Ensure proper ground and clean ground surface Have you inspected the consumables Reduce cutting speed Bring torch closer to work piece Ensure air passage way is free from debris Replace consumable...

Page 20: ...before honoring any parts warranty replacement repair Damage resulting from failure to use the product in a manner consistent with our recommendations shall render the limited warranty void This limit...

Page 21: ...authorized reproduction prohibited NOTES For comments and questions please email or write to Ramsond Corporation Public Relations Dept 4051 Haggerty Road West Bloomfield Michigan 48323 USA Tel 866 777...

Page 22: ...Instruction Manual Ramsond CUT series plasma cutters Rev 10 0993 Copyright Ramsond Corporation All rights protected Unauthorized reproduction prohibited...

Reviews: