- 11 -
n
WARNING
A non-contact sensor (photoelectric sensor or
equivalent) and a contact sensor (edge device or
equivalent) is required on each individual installa-
tion to comply with UL325.
Reversing Sensors
on the ground floor prevent
gate from closing when vehicle is in loop area.
Exit Loops
on the ground floor opens gate
when vehicle crosses loop area.
Master - Slave Installation
SENSOR INSTALLATION
6 feet min
typical
Inside
Property
Outside Property
Twist wires outside of loop
3 feet
min
Reversing
Loop
Reversing
Loop
Exit Loop
3 feet
min
3 feet
min
Figure 11
4 feet
min
4 feet min
4 feet
min
2-4 feet
Primary Operator is factory
pre-set for LH operation
Do not twist wires inside
loops.
1/4"
1-1/2"
Figure 12
Use 3-stranded, shielded
wires (not supplied) from
Master to Slave.
Use jumper
JP6 to JP6
SLAVE MODE
REVERSE LOGIC
JP6
Use jumper
JP6 to JP6
JP6
ON
Î
Set Dip Switch
“Slave Mode” to ON for Slave Operator.
RH operation requires Dip Switch “Reverse” to be ON.
Route low-voltage wires for
Master/Slave in a conduit
separate from power.