MANUALE ISTRUZIONI / INSTRUCTIONS MANUAL
MTR605/025/DASM - R605/027/DASM - R605/170/DASM
Modello/Model R605DASM
K/ 7
is
tru_
ca
lib
_605
.fm
7. The system will obtain the value and make the controls compared to previous val-
ues; it will then activate output 3 and deactivate output 2 in order to indicate it is
ready for the third operation.
8. Operator must set FFD at 120 cm and re-activate input 2 (M39 IRIS CLOSE), the
system usually follows up the control.
9. At the end of third operation, the operator can permanently save the obtained data
by re-activating inputs 1, 2, 3.
10.At every step of measurement, operator can decide to return to the previous input
1 (M38 IRIS OPEN). In this way the data can be replaced without repeating the
whole procedure. In other words, if 78 cm is achieved during the first step, because
it is the first step, it will not be possible to return to the previous phase, but in the
phase 100 cm it will be possible to return to 78 cm and from 120 cm phase it will be
possible to go down to 100 cm