Manual Mode:
This is the primary operation mode of the collimator.
Further to the configuration given to the system, the collimator determines set format
projection (with correct millimetric and rotation values) at a given FFD.
The format is selected from 8 preset dimensions or is received via ModBus or CAN-
Bus.
Manual movements are controlled and limited to the selected format. It is possible to
perform adjustments on open/close and rotation by 1mm and 1° at a time
Note
: The movements are at the operator's discretion and are not influenced by the
FFD.
Error Mode:
An Error occurs upon system operation anomalies. The following tables serves to trou-
bleshoot the causes:
Error Type
Problem description
Solution
Memory Access Error
The permanent memory
has been damaged or its
contents have been cor-
rupted.
Very rare occurrence.
Ask for technical assistance.
CAN DC STEP fails to
respond to the reset
control.
On power-up CAN DC
STEP transmits the end
stop search control to
the ASR003 boards. If a
confirmation is not pro-
duced, an error will set
in.
A probable cause is faulty
CAN connection or faulty
supply to the CAN DC STEP
boards.
Check on these connec-
tions.
End stop search time-
out.
CAN DC STEP has
received control to re-
set but one or more
movements have failed
to receive the relative en
stop within the allotted
time - 10s for simple
movements, 30 s for
two-motor movements,I
Observe the LEDs on CAN
DC STEP. Flickering Leds
indicate the end stop that
has timed out: Check on
electric and mechanical con-
nections of the end stop;
check that mechanisms are
not blocked.