![background image](http://html1.mh-extra.com/html/rais/attika-visio-series/attika-visio-series_installation-manual_3629977007.webp)
INSTALLATION MANUAL
Your new gas fireplace in general
This RAIS/ATTIKA product is a highly efficient convection gas fireplace with a sealed combustion
chamber for a balanced flue system. The fireplace has variable heating power and is equipped with a
burner which has been developed using the latest burner technology.
Before installation
All local laws and provisions should be studied before installation. Always check the national building
and gas regulations.
In addition, it should be confirmed that the information on the information plate relating to gas type
and gas pressure are in accordance with the local gas conditions that the fireplace shall be installed
under. The gas supply should be examined to ensure that it can supply the required amount of gas
and the required pressure.
It is recommended that gloves are worn when installing the gas fireplace to avoid fingerprints on
glass, etc.
Gas connection
This fireplace may only be installed, adjusted and serviced by
an authorised and qualified heating
and plumbing/gas technician
. The installation must comply with local and national building and gas
regulations, and the instructions in the installation manual must be followed. The installation manual
and user manual must be left with the customer, who must keep the manuals for later use. The manuals
are necessary when the fireplace is to be serviced.
The pipe on the gas hose has an external diameter of 8 mm or 10 mm, depending on the model.
When it has been determined where the fireplace shall be installed, a gas installation with a stopcock
in the vicinity of the fireplace must be executed to ensure that the gas supply and the fireplace can
be connected.
Since this fireplace is equipped with a sealed combustion chamber, a floor plate is not necessary.
If the fireplace is connected to bottled gas, it may only be connected to bottle gas that is equipped
with a gas regulator (low pressure regulator) that supplies the correct gas pressure.
Ensure that the balanced flue system is not blocked in any way and is free of vegetation in the form
of trees, bushes, etc.
The glass must always be cleaned on the outside before the fireplace is lit. Fingerprints must be wiped
off as these can burn into the glass.
GB - 6
GB
Summary of Contents for attika VISIO Series
Page 2: ......
Page 16: ...INSTALLATION MANUAL 5 Position the bottom grate above the burner 15 GB GB...
Page 26: ...INSTALLATION MANUAL INSTALLATION MANUAL 500 500 150 1000 50 Tunnel models 25 GB GB...
Page 72: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 71 GB GB...
Page 73: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE GB 72 GB...
Page 74: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 73 GB GB...
Page 75: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE GB 74 GB...
Page 76: ...INSTALLATION MANUAL DECLARATION OF PERFORMANCE 75 GB GB...
Page 77: ...INSTALLATION MANUAL DECLARATION OF CONFORMITY GB 76 GB...
Page 78: ...INSTALLATION MANUAL DECLARATION OF CONFORMITY 77 GB GB...
Page 98: ...INSTALLATIONSANLEITUNG 5 Bodengitter auf den Brenner legen 14 D D...
Page 108: ...INSTALLATIONSANLEITUNG INSTALLATIONSANLEITUNG 500 500 150 1000 50 Tunnelmodelle 24 D D...
Page 154: ...INSTALLATIONSANLEITUNG PR FBEST TIGUNG 70 D D...
Page 155: ...INSTALLATIONSANLEITUNG PR FBEST TIGUNG D 71 D...
Page 156: ...INSTALLATIONSANLEITUNG PR FBEST TIGUNG 72 D D...
Page 157: ...INSTALLATIONSANLEITUNG PR FBEST TIGUNG D 73 D...
Page 158: ...INSTALLATIONSANLEITUNG PR FBEST TIGUNG 74 D D...
Page 159: ...INSTALLATIONSANLEITUNG KONFORMIT TSERKL RUNG D 75 D...
Page 160: ...INSTALLATIONSANLEITUNG KONFORMIT TSERKL RUNG 76 D D...
Page 180: ...INSTALLATIONSVEJLEDNING 5 Plac r bundristen oven p burneren 14 DK DK...
Page 190: ...INSTALLATIONSVEJLEDNING INSTALLATIONSVEJLEDNING 500 500 150 1000 50 Tunnelmodeller 24 DK DK...
Page 236: ...YDEEVNEDEKLARATION 70 DK DK...
Page 237: ...INSTALLATIONSVEJLEDNING YDEEVNEDEKLARATION DK 71 DK...
Page 238: ...YDEEVNEDEKLARATION 72 DK DK...
Page 239: ...INSTALLATIONSVEJLEDNING YDEEVNEDEKLARATION DK 73 DK...
Page 240: ...YDEEVNEDEKLARATION 74 DK DK...
Page 241: ...INSTALLATIONSVEJLEDNING OVERENSSTEMMELSESERKL RING DK 75 DK...
Page 242: ...OVERENSSTEMMELSESERKL RING 76 DK DK...
Page 262: ...INSTALLASJONSVEILEDNING 5 Plasser bunnristen opp brenneren 14 NO NO...
Page 272: ...INSTALLASJONSVEILEDNING INSTALLASJONSVEILEDNING 500 500 150 1000 50 Tunnelmodeller 24 NO NO...
Page 318: ...INSTALLASJONSVEILEDNING YDEEVNEDEKLARATION 70 NO NO...
Page 319: ...INSTALLASJONSVEILEDNING YDEEVNEDEKLARATION NO 71 NO...
Page 320: ...INSTALLASJONSVEILEDNING YDEEVNEDEKLARATION 72 NO NO...
Page 321: ...INSTALLASJONSVEILEDNING YDEEVNEDEKLARATION NO 73 NO...
Page 322: ...INSTALLASJONSVEILEDNING YDEEVNEDEKLARATION 74 NO NO...
Page 323: ...INSTALLASJONSVEILEDNING SAMSVARSERKL RING NO 75 NO...
Page 324: ...INSTALLASJONSVEILEDNING SAMSVARSERKL RING 76 NO NO...
Page 344: ...INSTALLATIONSANVISNING 5 Placera bottengallret ovanp br nnaren 14 S S...
Page 354: ...INSTALLATIONSANVISNING INSTALLATIONSANVISNING 500 500 150 1000 50 Tunnelmodeller 24 S S...
Page 400: ...INSTALLATIONSANVISNING PRESTANDADEKLARATION 70 S S...
Page 401: ...INSTALLATIONSANVISNING PRESTANDADEKLARATION S 71 S...
Page 402: ...INSTALLATIONSANVISNING PRESTANDADEKLARATION 72 S S...
Page 403: ...INSTALLATIONSANVISNING PRESTANDADEKLARATION S 73 S...
Page 404: ...INSTALLATIONSANVISNING PRESTANDADEKLARATION 74 S S...
Page 405: ...INSTALLATIONSANVISNING F RS KRAN OM VERENSST MMELSE S 75 S...
Page 406: ...INSTALLATIONSANVISNING F RS KRAN OM VERENSST MMELSE 76 S S...
Page 407: ...INSTALLATIONSANVISNING FELS KNING FELS KNING Se bruksanvisningens avsnitt om fels kning S 77 S...
Page 435: ...TECHNICAL DRAWINGS TECHNICAL DRAWINGS 23 TECHNICAL DRAWINGS...
Page 436: ...TECHNICAL DRAWINGS 24 TECHNICAL DRAWINGS TECHNICAL DRAWINGS...
Page 437: ...TECHNICAL DRAWINGS TECHNICAL DRAWINGS 25 TECHNICAL DRAWINGS...
Page 438: ...TECHNICAL DRAWINGS 26 TECHNICAL DRAWINGS TECHNICAL DRAWINGS...