background image

 

 

 

 

PARTS LIST 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARRANTY 

This  System  is  warranted  to  the  original  Consumer  purchaser  for  a  period  of  one  (1)  year,  from  the  date  of  purchase,  against  defects  in  materials  or 
workmanship.  The  electronic  controls  and  mineral  tank  are  warranted  for  5  and  10  years  respectively  against  defects  in  materials  or  workmanship.  The 
company's  obligation  under  this  warranty  shall  consist  of  repair  or  replacement,  at  its  option,  of  any  part  found  by  company  inspection  to  be  defective, 
provided  that  the  product  has  not  been  misused,  abuse,  altered  or  damaged  by  Consumer  with  respect  to  the  original  installation,  as  determined  by  the 
company. This warranty will not apply if feed water does not meet specifications of this system. This limited Warranty applies only to a unit when returned to 
the  Warrantor  at  the  owner’s  expense  and  in  accordance  with  shipping  instructions  received  from  the  Warrantor.  This  warranty  does  NOT  cover,  and  is 
intended to exclude, any liability on the part of Envirogard for any incidental damages, consequential damages, labour charges or any other costs incurred in 
connection  with  the  purchase,  installation,  use,  maintenance  or  repair  of  the  system  whether  under  this  warranty  or  any  other  warranty  implied  by  law. 
Some provinces/states do not allow the exclusion of incidental or consequential damages, so the above  limitation or exclusion may not apply to you. This 
warranty gives you specific legal rights and you may also have other rights, which vary from province/state to province/state. This warranty applies only to 
water filter/systems purchased in Canada or the U.S.A. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

Envirogard Products Limited

6-446 Major Mackenzie Drive East,  

Richmond Hill, ON L4C 1J2, CANADA 

Toll Free:

 1800 667 8072 

Tel:

 (905) 884 9388 

Fax:

 (905) 884 3532  

E-Mail:

 [email protected]  

Web:

 www.rainfresh.ca 

S

ep

 2

01

5

 

10 

11 

 

DESCRIPTION 

CAFE Control Valve complete 

Inlet/Outlet Fitting - elbow (90°) – ¾” 

Locking clip for inlet/outlet 

Locking clip for bypass valve 

Bypass valve assembly 

Bypass valve metal clips and screw set 

Drain fitting (Elbow) 

Brine elbow fitting 3/8 stem x 3/8 QC 
with plug 

AC power adapter – 110V AC 

10 

Air Injector 

11 

Mineral tank 9” x 48” 

 

Summary of Contents for CAFE 948

Page 1: ...cking the unit 3 b Plumbing the Filter unit 4 c Start up and Programming 6 Other Features 8 Troubleshooting 8 Parts List 9 Warranty 9 SYSTEM SPECIFICATIONS Model No Rated Service Flow US GPM LPM Max Flow Rate US GPM LPM Backwash Flow Rate US GPM LPM Inlet Outlet Drain Connec tion Electrical Require ment Pressure Drop Operating Pressure Shipping Weight lbs CAFE 948 2 2 8 3 5 19 5 19 3 4 MNPT 1 2 Ho...

Page 2: ...AUTIONS BEFORE INSTALLATION Follow all plumbing codes for installation Your pump must be a submersible pump for the valve to operate properly Jet pumps often do not create enough suction for the air injector To operate properly the well pump flow rate must exceed the backwash flow rate 4 5 US GPM 17 LPM If your well pump does not deliver this flow rate do not install the unit as it will not work p...

Page 3: ...Injector 4 By pass valve Allen key with 2 metal clips and 2 screws 5 Two Male NPT elbow inlet outlet fittings 6 Drain Fitting for 1 2 Hose Hose not included Unpack the unit and place it at the location where you intend to install the unit Stand back and look at the main media tank and make sure it is standing straight up and not tilted to one side Sometimes during shipment the bottom of the tank w...

Page 4: ...ction of the inlet outlet pipes by simply rotating them Fig 4 Plumb in the inlet and outlet of the CAFE filter We recommend using Rainfresh CKS solder less connector kit for easy installation This can be ordered from the same retailer where you purchased the unit from or call Rainfresh Plumb in a flexible plastic drain line running from the filter black barbed elbow hose fitting Fig 5 This can be ...

Page 5: ... the main shutoff valve on all the way If you have no leaks proceed to the next steps Connect the control valve to the AC power source Fig 10 Manually put the CAFE filter into the regeneration cycle by pressing the SET REGEN button see page 6 Turn the bypass valve slightly more into the service position to allow water to run into the unit You want water to initially fill the tank slowly Once the t...

Page 6: ...5 Last Regeneration Date 6 Current Flow Rate GPM 7 Peak Flow Rate GPM The control valve has a display screen and 4 buttons VALVE PROGRAMMING The valve has 2 levels of programming Level 1 and Level 2 You will need to only go through Level 1 programming to start up your unit Level 2 programming is factory set and can be changed only if desired Level 1 programming allows you to set 1 Current time 2 C...

Page 7: ... default setting 8 Restore Default NO Leave at default Change only if you want to re start programming from start Press MENU for 3 seconds to unlock screen Press MENU again and the hour value becomes highlighted Press SET REGEN once again and the highlighted value flashes Now press or UP OR DOWN arrows to change the hour values Press SET REGEN again to accept the hour value and advance to change t...

Page 8: ...nutes During this time you may hear water running intermittently to the drain Care of Your Iron Filter To retain the attractive appearance of your new Iron Filter clean occasionally with mild soap solution Do not use abrasive cleaners ammonia or solvents TROUBLESHOOTING PROBLEM POTENTIAL CAUSE SOLUTION Filter fails to backwash 1 Electricity interrupted to system 2 Control head malfunction 1 Assure...

Page 9: ...d for any incidental damages consequential damages labour charges or any other costs incurred in connection with the purchase installation use maintenance or repair of the system whether under this warranty or any other warranty implied by law Some provinces states do not allow the exclusion of incidental or consequential damages so the above limitation or exclusion may not apply to you This warra...