HOW THE CAFE SYSTEM WORKS 

Your Rainfresh CAFE iron-removal filter utilizes oxidation and filtration technology to remove dissolved 
iron from water. Dissolved iron, also called ferrous iron is oxidized to a filterable rust form (ferric iron) 
which is then filtered out of the water. When the submersible pump is running, water is forced 
through an air-injector under high pressure. Inside the air-injector are two openings, one is a small 
venturi opening and the other is a larger 3/8” opening. The high-pressure water being forced through 
the small venturi opening creates a low pressure area inside the injector valve, which in turn draws 
extremely small micro-bubbles of air into the flow of water as it passes through the venturi opening.

 

The oxygen is utilized to oxidize ferrous (dissolved or clear water) iron to a filterable precipitate (ferric 
hydroxide). A special oxidant medium acts as an insoluble catalyst and enhances the oxidation process. 
After a pre-determined interval, an automatic 

backwash 

process is initiated wherein the “trapped” 

iron is stripped away and dumped to drain and the system is ready for use again. The backwash 
process is completely automatic and is factory set for 2 AM (can be changed).

 

Note: 

No salt or chemicals are required to clean the system. As such it is typically safe to dump the 

water into the septic system. However, because in every backwash cycle, about 45 gallons of water are 
used to clean the system, it is recommended that you consult a professional to ascertain the safety of 
the water going into your septic system. 

Note: 

CAFE systems do not kill or remove bacteria or any other pathogenic microorganisms. To 

continuously disinfect all the water in your house, we recommend that you install a Rainfresh UV 

system. Call Rainfresh for details. 
  

 
CAUTIONS BEFORE INSTALLATION 

 

Follow all plumbing codes for installation. 

 

Your pump must be a 

submersible pump 

for the valve to operate properly. Jet pumps often do not create enough 

suction for the air injector.  

 

To operate properly, the well pump flow rate must exceed the backwash flow rate (4.5 US GPM (17 LPM)). If your well 
pump does not deliver this flow rate, do not install the unit as it will not work properly. You may need to either change 
the well pump or call Rainfresh for a custom size unit that will operate within your pump specifications. 

 

The automatic control valve works on 110V AC. We recommend a GFI (ground fault interrupter) 120 volt outlet within 5 
feet of the filter. Extension cords are not recommended.  

 

CAFE systems do not kill or remove bacteria or any other pathogenic microorganisms. To continuously disinfect all the 
water in your house, we recommend that you install a Rainfresh UV system. Call Rainfresh for details. 

 

For use on cold water only. 

 

 

Only use thread seal tape 

(Teflon® tape)

 

for fitting connections into unit. 

DO NOT USE pipe dope or chemical sealants. 

 

 

If water pipes are used to ground electrical system, install jumper wire

 

(#4 gauge solid copper wire) across the unit to 

maintain proper grounding of your electrical system 

 

Protect your unit from freezing 

- drain the unit if freezing temperatures exist.

 

 

NOTE: IF SOLDER TYPE FITTINGS ARE USED DO NOT USE torch near inlet/outlet connections. 

All solder joints should be 

made before joining pipe to filter head.  

 

DO NOT over-tighten 

metal fittings on to unit connections.  

 

The unit should only be moved by 2 or more people due to heavy weight. Failure to do so can result in back or other 
injury. 

 

 
How to check well pump flow rate 

 

Make sure that the pressure tank is full and no one uses any water until you have finished the test. 

1)

 

Connect a hose to an appropriate outlet at the bottom of the pressure tank and put the other end into an empty 
pail of known volume (e.g. a 10 gal pail) 

Air Injection  

Iron Filter  

CAFE948 

Summary of Contents for CAFE 948

Page 1: ...cking the unit 3 b Plumbing the Filter unit 4 c Start up and Programming 6 Other Features 8 Troubleshooting 8 Parts List 9 Warranty 9 SYSTEM SPECIFICATIONS Model No Rated Service Flow US GPM LPM Max Flow Rate US GPM LPM Backwash Flow Rate US GPM LPM Inlet Outlet Drain Connec tion Electrical Require ment Pressure Drop Operating Pressure Shipping Weight lbs CAFE 948 2 2 8 3 5 19 5 19 3 4 MNPT 1 2 Ho...

Page 2: ...AUTIONS BEFORE INSTALLATION Follow all plumbing codes for installation Your pump must be a submersible pump for the valve to operate properly Jet pumps often do not create enough suction for the air injector To operate properly the well pump flow rate must exceed the backwash flow rate 4 5 US GPM 17 LPM If your well pump does not deliver this flow rate do not install the unit as it will not work p...

Page 3: ...Injector 4 By pass valve Allen key with 2 metal clips and 2 screws 5 Two Male NPT elbow inlet outlet fittings 6 Drain Fitting for 1 2 Hose Hose not included Unpack the unit and place it at the location where you intend to install the unit Stand back and look at the main media tank and make sure it is standing straight up and not tilted to one side Sometimes during shipment the bottom of the tank w...

Page 4: ...ction of the inlet outlet pipes by simply rotating them Fig 4 Plumb in the inlet and outlet of the CAFE filter We recommend using Rainfresh CKS solder less connector kit for easy installation This can be ordered from the same retailer where you purchased the unit from or call Rainfresh Plumb in a flexible plastic drain line running from the filter black barbed elbow hose fitting Fig 5 This can be ...

Page 5: ... the main shutoff valve on all the way If you have no leaks proceed to the next steps Connect the control valve to the AC power source Fig 10 Manually put the CAFE filter into the regeneration cycle by pressing the SET REGEN button see page 6 Turn the bypass valve slightly more into the service position to allow water to run into the unit You want water to initially fill the tank slowly Once the t...

Page 6: ...5 Last Regeneration Date 6 Current Flow Rate GPM 7 Peak Flow Rate GPM The control valve has a display screen and 4 buttons VALVE PROGRAMMING The valve has 2 levels of programming Level 1 and Level 2 You will need to only go through Level 1 programming to start up your unit Level 2 programming is factory set and can be changed only if desired Level 1 programming allows you to set 1 Current time 2 C...

Page 7: ... default setting 8 Restore Default NO Leave at default Change only if you want to re start programming from start Press MENU for 3 seconds to unlock screen Press MENU again and the hour value becomes highlighted Press SET REGEN once again and the highlighted value flashes Now press or UP OR DOWN arrows to change the hour values Press SET REGEN again to accept the hour value and advance to change t...

Page 8: ...nutes During this time you may hear water running intermittently to the drain Care of Your Iron Filter To retain the attractive appearance of your new Iron Filter clean occasionally with mild soap solution Do not use abrasive cleaners ammonia or solvents TROUBLESHOOTING PROBLEM POTENTIAL CAUSE SOLUTION Filter fails to backwash 1 Electricity interrupted to system 2 Control head malfunction 1 Assure...

Page 9: ...d for any incidental damages consequential damages labour charges or any other costs incurred in connection with the purchase installation use maintenance or repair of the system whether under this warranty or any other warranty implied by law Some provinces states do not allow the exclusion of incidental or consequential damages so the above limitation or exclusion may not apply to you This warra...

Reviews: