STARTUP & PROGRAMMING 

The control valve is pre-programmed at factory. You can however change the default settings or to change regeneration 
frequency. We recommend setting backwash every 3 days with a minimum 10 minute backwash and 5 minute rinse cycle. If 
you have questions about programming, please call Rainfresh at 1800-667-8072. 

When power is first supplied, the valve electronics may take up to two minutes to initialize.  During this time the screen will 
show “INTIALIZING WAIT PLEASE”.  Do not touch any buttons at this time.  When the valve reaches the service position, it 
will display the following information in sequence:

  

 

1.

 

Date & Time 

2.

 

Regeneration Days/Capacity 

3.

 

Remaining Days/Volume Remaining 

4.

 

Regeneration Time 

5.

 

Last Regeneration Date 

6.

 

Current Flow Rate (GPM) 

7.

 

Peak Flow Rate (GPM)

The control valve has a display screen and 4 buttons 

 

 

 

 

 

 

 

 
 
 
 
 
 
 

 
VALVE PROGRAMMING

 

The valve has 2 levels of programming – Level 1 and Level 2 
You will need to only go through Level 1 programming to start up your unit. Level 2 programming is factory set 
and can be changed only if desired. 
 
Level 1 programming allows you to set  

1.

 

Current time 

2.

 

Current date 

3.

 

Vacation mode  

 

 
 
 
 
 
 
 
 
 
 

MENU BUTTON

 

“ ” 

The function of this key is to 
enter the level one 
programming mode where the 
valve settings can be adjusted. 

SET / REGEN BUTTON

 

” 

This button has two functions.  The first is to initiate a 
manual regeneration by holding the button for 3 or 
more seconds.  The second function is while in 
programming mode, pressing this key allows the user to 
change the value of each setting. 

UP / DOWN

 

” 

These buttons are used to 
increase or decrease the value 
of the settings while in the 
programming mode. 

Summary of Contents for CAFE 948

Page 1: ...cking the unit 3 b Plumbing the Filter unit 4 c Start up and Programming 6 Other Features 8 Troubleshooting 8 Parts List 9 Warranty 9 SYSTEM SPECIFICATIONS Model No Rated Service Flow US GPM LPM Max Flow Rate US GPM LPM Backwash Flow Rate US GPM LPM Inlet Outlet Drain Connec tion Electrical Require ment Pressure Drop Operating Pressure Shipping Weight lbs CAFE 948 2 2 8 3 5 19 5 19 3 4 MNPT 1 2 Ho...

Page 2: ...AUTIONS BEFORE INSTALLATION Follow all plumbing codes for installation Your pump must be a submersible pump for the valve to operate properly Jet pumps often do not create enough suction for the air injector To operate properly the well pump flow rate must exceed the backwash flow rate 4 5 US GPM 17 LPM If your well pump does not deliver this flow rate do not install the unit as it will not work p...

Page 3: ...Injector 4 By pass valve Allen key with 2 metal clips and 2 screws 5 Two Male NPT elbow inlet outlet fittings 6 Drain Fitting for 1 2 Hose Hose not included Unpack the unit and place it at the location where you intend to install the unit Stand back and look at the main media tank and make sure it is standing straight up and not tilted to one side Sometimes during shipment the bottom of the tank w...

Page 4: ...ction of the inlet outlet pipes by simply rotating them Fig 4 Plumb in the inlet and outlet of the CAFE filter We recommend using Rainfresh CKS solder less connector kit for easy installation This can be ordered from the same retailer where you purchased the unit from or call Rainfresh Plumb in a flexible plastic drain line running from the filter black barbed elbow hose fitting Fig 5 This can be ...

Page 5: ... the main shutoff valve on all the way If you have no leaks proceed to the next steps Connect the control valve to the AC power source Fig 10 Manually put the CAFE filter into the regeneration cycle by pressing the SET REGEN button see page 6 Turn the bypass valve slightly more into the service position to allow water to run into the unit You want water to initially fill the tank slowly Once the t...

Page 6: ...5 Last Regeneration Date 6 Current Flow Rate GPM 7 Peak Flow Rate GPM The control valve has a display screen and 4 buttons VALVE PROGRAMMING The valve has 2 levels of programming Level 1 and Level 2 You will need to only go through Level 1 programming to start up your unit Level 2 programming is factory set and can be changed only if desired Level 1 programming allows you to set 1 Current time 2 C...

Page 7: ... default setting 8 Restore Default NO Leave at default Change only if you want to re start programming from start Press MENU for 3 seconds to unlock screen Press MENU again and the hour value becomes highlighted Press SET REGEN once again and the highlighted value flashes Now press or UP OR DOWN arrows to change the hour values Press SET REGEN again to accept the hour value and advance to change t...

Page 8: ...nutes During this time you may hear water running intermittently to the drain Care of Your Iron Filter To retain the attractive appearance of your new Iron Filter clean occasionally with mild soap solution Do not use abrasive cleaners ammonia or solvents TROUBLESHOOTING PROBLEM POTENTIAL CAUSE SOLUTION Filter fails to backwash 1 Electricity interrupted to system 2 Control head malfunction 1 Assure...

Page 9: ...d for any incidental damages consequential damages labour charges or any other costs incurred in connection with the purchase installation use maintenance or repair of the system whether under this warranty or any other warranty implied by law Some provinces states do not allow the exclusion of incidental or consequential damages so the above limitation or exclusion may not apply to you This warra...

Reviews: