11
ESP-LXD Controller
Alarm Conditions
An alarm condition can occur when programming omissions or other
issues prevent normal irrigation.
Decoder Address Alarms
The controller will alarm if duplicate decoder addresses are entered
for one or more weather sensors, flow sensors or stations. To clear the
alarm, enter a different decoder address for one of the decoders. Only
the first two duplicates will be shown, so you may need to repeat this
process until all duplicate addresses have been cleared.
FloWatch
TM
Alarms
The controller will alarm for certain flow conditions if you have FloWatch
set up. See Section F, Flow Management for more details.
Review Alarm Messages
A
When an alarm condition is detected, the alarm light on the
controller front panel will illuminate.
1
b
g
Turn the controller dial to AUTO.
B
When an alarm condition is present, the Alarm button label will be
present on screen. Press the Alarm button to view alarm details.
C
Any present alarm conditions will then be displayed. Press the
Next button if necessary, to advance to the next page.
b
c
b
b
NOTE:
Take the appropriate action to address each alarm
condition. When all alarms have been addressed, the alarm light
on the front panel will no longer be illuminated.
Summary of Contents for ESP-LXD
Page 1: ...ESP LXD Controller Installation Programming Operation Guide...
Page 6: ...this page intentionally left blank...
Page 34: ...28 ESP LXD Controller this page intentionally left blank...
Page 45: ...39 ESP LXD Controller this page intentionally left blank...
Page 52: ...46 ESP LXD Controller this page intentionally left blank...
Page 82: ...76 ESP LXD Controller this page intentionally left blank...
Page 104: ...98 ESP LXD Controller this page intentionally left blank...
Page 115: ...109 ESP LXD Controller this page intentionally left blank...
Page 134: ...128 ESP LXD Controller this page intentionally left blank...