
ESP-LX Modular Controller
37
MV or Pump
The ESP-LX Modular controller has a connection for a single
master valve or pump start relay. You can set the master
valve/pump output on or off for each valve. If the output is on, any
time the valve operates, the master valve or pump start relay will
also turn on. For example, if a specific valve needs additional water
pressure, you may want to activate a booster pump whenever that
valve turns on. The default setting is on.
CAUTION:
If an unused valve is turned on and
activates a pump start relay, the pump may overheat
or cause a pipe to burst. To prevent operating a pump
with no flow (deadheading), make sure that all unused
valves have a zero run time or that the MV or pump
start output is off for unused valves.
Turn the dial to “VALVE SETTINGS.”
The Valve Settings menu appears.
Press “3” on the Valve Settings menu.