![RAE-SAN V1.02 OBD-Bridge Installation Manual Download Page 17](http://html1.mh-extra.com/html/rae-san/v1-02-obd-bridge/v1-02-obd-bridge_installation-manual_781286017.webp)
The custom PID definitions in the setup I use are as follows.
As the output ranges defined for the sensors affects the value reported and hence the PID values sent, these are
shown in the other columns of the table to show the interdependence.
Standard PIDS
Standard Pids –
already defined
Custom Pids –
need to be defined
PID
Quantity
OutMin
OutMax
unit
Internal
range
Suggested Formula
Min
Max
0105
Coolant
TEMP
40.0
130.0
Deg C
0-3000
A - 40
-40
215
012F
FUEL
10.0
100.0
%
0-1000
(100 *A)/255
0
100
015C
OIL TEMP
40.0
150.0
Deg C
0-3000
A - 40
40
150
01B0
OIL
PRESSURE
7.0
100.0
PSI
0-2000
Int16(a:b)/10
(a*256+b)/10
0.0
110.0
0111
TPS
0.0
100.0
%
0-1000
(100 *A)/255
0
100
019C
O2 SENSE
9.0
19.0
A/F
900-1900
Int16(a:b)/100
(a*256+b)/100
8.0
20.0
0142
Voltage
0.0
21.0
V
0..21000
Int16(a:b)/1000
0.0
21.0
010D
SPEED
0.0
255
Km/h
0-255
Int8(a)
0.0
255.0
010C
TACHO
0.0
16384
RPM
0-1000
(eg)
Int16(a:b)/4
0
16000
015E
Engine Fuel
Rate
0.0
65536
l/hr
0-65.536
Int16(a:b)/20
0
65.5
01B3
Cooling Fan
On
0
1
-
0..1
A
0.0
1.0
01B1
High Beam
0
1
-
0..1
A
0.0
1.0
01B4
Low Fuel
Warn
0
1
-
0..1
A
0.0
1.0
01A6
Odometer
0.0
100000000 10cm
Int32
Int32(a:b:c:d)/100
0.0
100000.0
Summary of Contents for V1.02 OBD-Bridge