MNC-0400-001
26 of 54
REV H
Operation, Rack and Digital HPAs
Set Min Power Menu
The
Set Min Power Menu
(Figure 10) allows you to control the
minimum power detection circuits.
The front panel 10-key pad and three of the softkeys of the
Set
Min Power Menu
are active. The front panel 10-key pad is used
to enter the desired minimum power level.
Entries are in the units shown on the second line. Press [
Clear
]
to clear your entry. Press [
Enter
] to accept your entry.
The
Set Min Power Menu
softkey functions are:
[Softkey 1]—
Cycles one step each time the softkey is pressed.
The step sequence is:
OFF ALARM FAULT OFF etc.
These three states are:
OFF —
Disables the minimum power detection circuit
alarm and faults,
ALARM
— Enables the minimum power detection circuit
alarm. The display will show the Alarm and the buzzer
will sound but High Voltage will NOT be shut off.
FAULT
— Enables the minimum power fault detection
circuit. The display will show Fault; the buzzer will sound
and the High Voltage will shut off.
[Softkey 2]—
Not Used. Numeric value shown on the line to the
left of this softkey is the current minimum power level setting.
[Softkey 3]—
Not Used. (Value you enter from the keypad is
displayed to the left of this key.)
Entries are in the units shown on the second line.
[Softkey 4]—
Pressed to return to the
Alarms/Faults Menu
.
Set Maximum Reflected Power Menu
The
Set Max Reflected Power Menu
(Figure 10) allows you to
control the maximum power detection circuits.