![Radyne Xicom XTRD-400K Operation And Installation Manual Download Page 133](http://html1.mh-extra.com/html/radyne/xicom-xtrd-400k/xicom-xtrd-400k_operation-and-installation-manual_3359535133.webp)
MNC-0500-002
21 of 36
Revision H
Amplifier Communication and Protocol, Octagon ISA CPU
Alarm Condition
Command Byte
: '9'
Response
: One byte of alarm status, formatted as follows.
Bit 7: Reserved.
Bit 6: Complement of bit 5.
Bit 5: High Output Power.
Bit 4: Low Output Power.
Bit 3: High Reflected Power (VSWR).
Bit 2: Reserved.
Bit 1: Reserved.
Bit 0: Reserved.
Notes
:
Low Output Power, High Output Power and High Reflected Power are user-defined
alarms.
Compatibility
: Not available when querying analog amplifiers via a controller.
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.