Unpacking and Installation
MNC-0300-001
15 of 20
Revision L
Figure 8, Three Phase Delta Connection into MS type connector
Serial Interface Ports
Dual serial interface connectors (COM1 and COM2), located on
the rear panel of the amplifier are available for remote control
operation. Both serial interface ports are always enabled. The
amplifier will respond to commands from either interface. The
Table 4, Three Phase Delta Connection Pinouts (Amphenol)
Pin
Connection
1
Phase A
2
Phase B
3
Phase C
4
Ground
Table 5, Three Phase Delta Connection into MS type Connec-
tor
Terminal
Connection
A
Phase A
B
Phase B
C
Phase C
D
No Connection