MNC-0500-002
29 of 36
Revision H
Amplifier Communication and Protocol, Octagon ISA CPU
Clear RF Inhibit
Command Byte
: 'J'
Function
: RF drive to the TWT is enabled.
Compatibility
: Attenuator required.
Set Attenuator
Command Byte
: 'K'
Parameter:
“XX.X” dB of attenuation OR
“IX.X” to increase attenuation by X.X OR
“DX.X” to decrease attenuation by X.X
Function
: Instantly sets the attenuator to the specified dB level. Use caution, as sudden
large changes to output power can damage the tube.
Response:
Resulting attenuation in XX.X dB. If the user specified an attenuation value
outside the attenuator’s range, the closest valid value will be used.
Note:
Use this to find max attenuation. For example, send {AK 99.9}. A typical
response would be {AK 30.0}, indicating a 30 dB attenuation range.
Compatibility
: Attenuator required.
Min RF Power Trip
Command Byte
: 'L'
Function
: Sets a Min RF trip point. If output power drops below the set point, an alarm
or fault is generated provided the HPA has processed an “Enable RF Limits” command
('R').
Parameter
:
"AXXXX" to set an Alarm trip point,
"FXXXX" to set a Fault trip point, “D” to disable.
XXXX is the desired trip point in Watts.
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.