- 60 -
o
Which opens a window for
entering name of a part to be
saved
o
Accept entered name by
pressing ENTER button – a part
is automatically added to the
DATABASE of STANDARDS.
Mass of the saved part is
previewed next to the name of a
saved standard.
RECALL STANDARD FROM
THEDATABASE
o
In the parts counting mode press
quick access key to enter
DATABASE OF STANDARDS
o
Press name of a standard to be
acquired from the database
o
The software automatically
returns to the parts counting
mode
o
Mass of a recalled standard is
indicated in the workspace area.
xxxx
The default value for the function on: Setting standard mass
enter a number denoting quantity of parts used for calculating mass of a
signle part on weighing process /see pictogram description: set standard
mass/
Checkweighing
When in the menu, determine presence of the checkweighing hot-key in the
bottom bar of the display. Set parameter option to: YES.
Pressing the checkweighing pictogram in the bottom bar enables setting the
LOW and HIGH checkweighing thresholds. Enter total value of parts quantity.
Return to weighing: press ARROW pictogram for returning to weighing.
Dosing
When in the menu, determine presence of the filling hot-key in the bottom bar
of the display. Set parameter option to: YES.
Pressing the filling pictogram in the bottom bar enables setting a target value
to be filled (dosed). Enter total value of parts quantity. Return to weighing:
press ARROW pictogram for returning to weighing.
Statistics
Each pressing of PRINT button or an automatic printout action causes adding
a weighing result to STATISTICS.
Calculation of statistics includes: quantity, total sum, average, MIN value,
MAX value, max-min difference, standard deviation, variance coefficient
User defined hot-keys
The user defined hot-keys enable assigning an optional process to the hot-
key.
Summary of Contents for MYA 0,8Y
Page 2: ...2 APRIL 2013...