background image

 

 

 

Ramp scales 

Livestock 

scales 

Track scales

 

Waterproof platform 

scales 

 

Pl

a

tf

o

rm

 

w

it

h

 ra

m

p

s

 

W

e

ig

h

in

g

 i

n

d

ic

a

to

Pl

a

tf

o

rm

 

w

it

h

 c

a

g

e

 

W

e

ig

h

in

g

 i

n

d

ic

a

to

L

o

a

d

-b

e

a

ri

n

g

 

s

tru

c

tu

re

 

w

it

h

 a

 l

o

a

d

 c

e

ll

 

W

e

ig

h

in

g

 i

n

d

ic

a

to

Pl

a

tf

o

rm

 

W

e

ig

h

in

g

 i

n

d

ic

a

to

U

n

in

s

ta

lle

d

 p

a

n

 

Water with 
detergents 

Yes 

Yes

 

Yes

 

Yes

 

Yes

 

Yes

 

Yes

 

Yes

 

Yes

 

Intense water jet 

Yes 

No 

Yes 

No 

Yes 

No 

No 

No 

Yes 

Hot water, 80°C 

max 

Yes 

No 

Yes 

No 

Yes 

No 

No 

No 

Yes 

 
 

4. SERVICE AND REPAIR  

 

 

In case of any sign of damage, it is necessary to disconnect 
the  device  form  the  mains  immediately.  The  damaged 
component  must  be  replaced  or  repaired  by  RADWAG 
service directly. 

 

In case of any problems with correct operation of the scale, contact the closest 
manufacturer's  service  point.  In  case  of  defects,  deliver  the  faulty  product  to  
the  manufacturer's  service  point.  If  the  product  cannot  be  delivered  to  
the manufacturer's service point, call the service and report the defect. Repair 
scope and method will be set up. 

 

 

The  user  is  NOT  ALLOWED  to  carry  out  any  kind  of  repair  
of  the  device  himself/herself.  Any  attempt  of  scale 
modification, repair etc., by unauthorized persons, will result 
with  loss  of  validity  of  manufacturer-issued  certificates, 
declarations and warranty. 

 
 

5. RECYCLING 

 

HY10  scales  must  be  recycled,  they  are  not  to  be  treated  as  a  regular 
household  waste.  Scales  to  be  decommissioned  must  be  decommissioned  
in accordance with valid legal regulations. 

Summary of Contents for HY10 Series

Page 1: ......

Page 2: ...2 SEPTEMBER 2020 ...

Page 3: ...ing sharp edged tools knife screwdriver etc Protect the indicator against considerable temperature variation solar and UV radiation substances causing chemical reactions The indicator must not be operated in hazardous areas endangered with explosion of gases and in dusty environments In case of damage immediately unplug the device from the mains Scales to be decommissioned must be decommissioned i...

Page 4: ... 8 Operation Panel 14 7 INSTALLATION 15 7 1 Unpacking and Installation 15 7 1 1 1 Load Cell Multifunctional Scales 15 7 1 2 Platform Scales HY10 4 xx C HY10 4 xx H HY10 4 xx H Z Series 15 7 1 3 Ramp Scales HY10 4N Series 15 7 1 4 Track Scales HY10 2K Series 16 7 2 Levelling 1 Load Cell Platform Scales 17 7 3 Levelling 4 Load Cell Platform Scales 17 7 4 Start Up 17 8 HOME SCREEN 18 8 1 Top Bar 18 8...

Page 5: ...WARRANTY CONDITIONS A RADWAG feels obliged to repair or exchange all elements that appear to be faulty by production or by construction B Defining defects of unclear origin and means of their elimination can only be realized with assistance of the manufacturer and user representatives C RADWAG does not bear any responsibility for damage or losses resulting from unauthorized or inadequate performin...

Page 6: ...se or cotton You can use a solution of water and detergent soap dishwashing detergent glass cleaner Gently rub the dirty surface and let it dry Repeat the cleaning process if necessary In the case of hard to remove contamination e g residues of adhesive rubber resin polyurethane foam etc you can use special cleaning agents based on a mixture of aliphatic hydrocarbons that do not dissolve plastics ...

Page 7: ... indicators of all scales feature stainless steel housing polyester overlay and polyamide glands Platforms of both livestock and ramp scales their load bearing structures and weighing tracks can be water jet cleaned the water temperature must be up to 80 C respective cleanser needs to be added When it comes to indicators it is forbidden to apply water jet cleaning method use of hot water is not al...

Page 8: ...ice directly In case of any problems with correct operation of the scale contact the closest manufacturer s service point In case of defects deliver the faulty product to the manufacturer s service point If the product cannot be delivered to the manufacturer s service point call the service and report the defect Repair scope and method will be set up The user is NOT ALLOWED to carry out any kind o...

Page 9: ...coated steel 1 load cell scale design the main components 1 load cell scale design the main components 1 weighing pan 2 cross 3 load cell 4 base 6 2 Multiple Load Cell Scales Multiple load cell HY10 scale is intended to carry out fast and precise mass measurement of large loads Its characteristic feature is a platform equipped with numerous load cells usually four The platform depending on a scale...

Page 10: ...0 scale with load cell modules is intended to carry out mass measurement of silos The modules are built into construction of ground fixed silo s support In most cases the scale design includes 3 4 load cell modules The modules depending on the model are made of stainless or galvanized steel Scale design the main components Scale design the main components 1 module 2 junction box ...

Page 11: ...nectors 1 Grounding terminal 2 Power cord cable gland 3 USB A connector 4 USB M12 4P connector 5 RS232 1 M12 8P connector 6 Ethernet RJ45 connector 7 4OUT M12 8P connector 8 4IN M12 8P connector 9 Platform 1 cable gland 10 Platform 2 cable gland 11 Spot intended for cable gland additional equipment connector Vk3 12IN PROFIBUS IN mounted depending on indicator type by default plugged ...

Page 12: ...ector 16 Power supply switch 6 6 Pins Assignment RS232 Pin1 NC Pin2 RxD Pin3 TxD Pin4 NC Pin5 GND Pin6 5VDC Pin7 GNDZ Pin8 24VDC PROFIBUS IN male Pin1 NC Pin2 A Pin3 NC Pin4 B Pin5 NC PROFIBUS OUT female Pin1 5V Pin2 A Pin3 GND Pin4 B Pin5 NC USB Pin1 Vcc Pin2 D Pin3 D Pin4 GND 6 7 Inputs Outputs Standard HY10 terminal is equipped with 4 optoisolated inputs and 4 semiconductor outputs solid state ...

Page 13: ...arameters Output quantity 4 Output type Solid state relay Cable cross section 0 14 0 5 mm 2 Maximum output current 0 5 A DC Maximum output voltage 30 VDC AC Input parameters Input quantity 4 Input type Optoisolated Cable cross section 0 14 0 5 mm 2 Input voltage range 5 24 VDC 6 7 2 I O Schematic Diagrams 4 inputs 4 outputs ...

Page 14: ...ck Press to enter the menu Press to go to the home screen Press to log in Press to zero the scale Press to tare the scale Press to send the weighing result to a printer or a computer Press to delete the last character Dot character Numeric keys ...

Page 15: ... and install the weighing pan 7 1 2 Platform Scales HY10 4 xx C HY10 4 xx H HY10 4 xx H Z Series Take the device out of the packaging pallet Place the device on a flat and even surface Keep it away from any sources of heat Remove transport locks if installed Fix the feet if not installed 7 1 3 Ramp Scales HY10 4N Series Take the device out of the packaging pallet Prior to installation mount a stee...

Page 16: ...load bearing structure and load cells measuring components The scale is installed on a rail of the load bearing structure of the suspended track the load cell is installed in a particular section of the track The scale must be installed by an authorized RADWAG service exclusively otherwise the warranty gets null and void During scale installation attention must be paid to stresses and the weighing...

Page 17: ... turned left and right turning causes tilt Adjustment span of the scale level is narrow therefore the correct level is obtained using steel washers which are to be put under the feet Keep turning the feet until the air bubble takes central position 7 4 Start Up Turn the power on do it by pressing ON OFF switch located at the back of the indicator housing Operating system loading begins Upon comple...

Page 18: ...w to configure the home screen is to be found in PUE HY10 Indicator Software Manual 8 1 Top Bar The top bar displays the following information Working mode name and symbol Login entry Symbol informing that communication with a PC is on Symbol informing that communication with the E2R SYSTEM is on Weighing device name Date and time ...

Page 19: ... go to the home screen directly Press to go back Press to go back Press to scroll the menu up Press to scroll the menu down Press to scroll the menu up down fast Press to confirm modifications Press to exit the parameter remains unmodified Press to add a database record Press to disable the selected record User logout Press to search a particular database record by date Press to search a particula...

Page 20: ...turn to the home screen To return to the home screen press key repeatedly keep pressing the key until you see the home screen press either button or field both located in the top bar the home screen is displayed immediately 10 WEIGHING Load the weighing pan Read the result when stability marker is displayed 10 1 Operation conditions for 1 load cell scales To assure long term operation and correct ...

Page 21: ... not apply concentrated force total load in one point Avoid side loading in particular side shocks 10 2 Operation conditions for special scales It is forbidden to apply load other than intended for a particular scale beam scales self supporting rigid load or load placed in rigid load transferring packaging pallet scales load placed on EUR pallet using pallet truck middle block of pallet placed on ...

Page 22: ...ure that in case of trucks of weight close to maximum capacity the load is transferred onto platform close to load carrying sections profiles track scales product hanging on a hook intended to slide hooks suiting a particular track and scale smooth slide down the track no jerky moves no swinging left or right evenly loaded track ...

Page 23: ...23 11 DIAGRAMS OF CONNECTION CABLES Indicator computer cable Indicator printer cable EPSON Indicator printer cable ZEBRA ...

Page 24: ...24 USB adapter cable Indicator barcode scanner cable LS2208 Indicator PRINT TARE ZERO STOP cable ...

Page 25: ...e Scale Ethernet cable is a standard network cable terminated with RJ45 connectors on both ends 12 TECHNICAL SPECIFICATIONS For technical specifications of respective scales go to RADWAG website www radwag pl 13 ERROR MESSAGES ...

Page 26: ...26 ...

Reviews: