If  you  wish  to  limit  the  room  temperature  to  a  
predefined level:
•  Remove the temperature knob. 
  Find  the  temperature  indicators  [see  diagram  

opposite] and place the pins there.

•  Place the knob back on the thermostat.

REPLaCiNG EMiTTER BaTTERiES

Batteries  must  be  replaced  when  the  receiver  does 
not register orders sent by the emitter [low batteries] 
or  when  the  light  [5]  doesn’t  react  to  operations  
carried out on the emitter [flat batteries].
•  Replace the batteries with 

2 new flat CR2430 type 

batteries.

SPECifiC RECOMMENdaTiONS

When using, you may notice that the upper and lower 
parts of the appliance are not as hot as the rest of it:
•  The  upper  parts  are  not  completely  full  to  allow 

for the heat-conductor liquid to expand when the  
device is switched on.

•  The lower parts carry the liquid on its return cycle 

after it has transmitted its heat.

SPECifiC  CaSE  Of  REGuLaTiNG  
uSiNG ThE PiLOT wiRE [BLaCK wiRE]

Your  appliance  enables  you  to  manage  orders  sent 
by EDF [cf. Tempo rates].  It also enables you to view 
them using display [A] or [F] [depending on how the 
device is equipped]:
1.  Comfort: constant green light.
2.  Reduced: flashing green light 
  [3,5°C below set temperature].
3.  Freeze  protection  mode:  light  is  off  with  green 

flashes [set temperature=7°C].

4.  Off: Light is off.
5.  Comfort -1°C: green light with single blink. 
6.  Comfort -2°C: green light with double blink.

Orders generated by the user.
Orders generated by EDF.

MaiNTENaNCE

Use a soft, dry cloth to clean the control box. 
Never use abrasive cleaning products.

TEChNiCaL SPECifiCaTiONS

Min 15°C 

Min 15°C

Max 25°C

Margin for measuring 
temperature

0.1°C [receiver]

Margin for setting the 
temperature

0.5°C

Range of temperature 5°C -30°C

Electrical protection

Receiver: Class II - IP44

Power [receiver]

12A / 250V RELAIS 16A

Batteries [emitter]

2  flat  CR2430  type  
batteries  provided  [with 
an  approximately  24 
month life]

Summary of Contents for CONTROL BOX

Page 1: ...the room temperature measured is higher than 35 C The infrared receiver has an autonomous regulation system which memorises the status information on standby and temperature instructions Storing the last instruction received means that the temperature can be regulated even if the emitter is off batteries have run out for example IMPORTANT if your receiver is off your appliance will not receive the...

Page 2: ...oost The second 2 hour Boost will start immediately and will repeat after 13 hours and 15 minutes and then every 24 hours NOTE You can stop the timer at an time by pressing the OK Boost button briefly Changing a programmed Boost Turn the cursor 8 to the chosen programme and at the desired time press the OK Boost button for 3 seconds the new cycle will be saved and the previous one will be erased N...

Page 3: ... transmitted its heat Specific case of regulating using the pilot wire black wire Your appliance enables you to manage orders sent by EDF cf Tempo rates It also enables you to view them using display A or F depending on how the device is equipped 1 Comfort constant green light 2 Reduced flashing green light 3 5 C below set temperature 3 Freeze protection mode light is off with green flashes set te...

Page 4: ...l Le voyant 1 s allume Etats du voyant 1 Eteint Veille manuel bouton ou arrêt par fil pilote Vert fixe appareil en fonctionnement Rouge fixe appareil en chauffe Rouge clignotant appareil en mode Boost marche forcée Vert Rouge clignotant défaut de sonde hors service ou surchauffe la température ambiante mesurée est supérieure à 35 C Le récepteur infrarouge dispose d un système de régulation autonom...

Page 5: ...t 3 secondes Le lendemain et les jours suivants l appareil se met en chauffe à 6 heures 15 pour une durée de 2H A la fin du Boost la régulation revient en mode confort Programmation de la 2ème répétitivité quotidienne P2 Positionner le curseur 8 sur P1 P2 Procéder comme pour la programmation du Boost P1 Le 2ème boost 2H se met en route immédiate ment et se répétera au bout de 23h15 et ensuite tout...

Page 6: ...vent le retour du fluide qui a transmis sa chaleur Cas particulier de régulation par fil pilote fil noir Votre appareil permet de gérer les ordres envoyés par EDF cf tarif Tempo Il permet également de les visualiser grâce au voyant A ou F selon équipement de l appareil 1 Confort voyant vert fixe 2 Réduit voyant vert clignotant consigne réduite de 3 5 C 3 Hors gel voyant éteint avec flashs vert con...

Page 7: ...hakelen Het indicatorlampje 1 licht op Statussen van het indicatorlampje 1 Uit handmatige waakstand knop of uitschakelen via stuurdraad Continu groen toestel is in werking Continu rood toestel warmt op Rood knipperen toestel in Boost modus geforceerde gang Groen rood knipperen defect aan sonde buiten werking of oververhitting de gemeten omge vingstemperatuur 35 C De IR ontvangstsensor is uitgerust...

Page 8: ...conden lang ingedrukt De volgende dag en de volgende dagen slaat het toestel op om 6 15 u voor een duur van 2u Na de Boost wordt overgeschakeld op de modus comfort Programmeren van de tweede dagelijkse P2 cyclus Plaats de cursor 8 op P1 P2 Ga verder zoals voor het programmeren van Boost P1 De 2e Boost treedt onmiddellijk in werking gedurende 2 u en zal dit herhalen na 23 15 u en vervolgens om de 2...

Page 9: ...nder geval van regeling via stuurdraad zwarte draad Uw toestel laat toe om commando s te beheren die door EDF bv tarief Tempo worden verzonden Via indicatorlampjes A of F al naargelang de uit rusting van het toestel kunt u ze visualiseren 1 Comfort permanent groen indicatorlampje 2 Verlaagd knipperend groen indicatorlampje inge stelde temperatuur verlaagd met 3 5 C 3 Vorstvrij indicatorlampje uitg...

Page 10: ...10 ...

Reviews: