DIGITAL THERMOSTAT
USER MANUAL ver 1.3
LCD Symbols
Turning on/off the
thermostat
Temporary temperature
The buttons are locked
The program number
Heating is turned on
Comfort temperature
mode
Room temperature
Economy temperature
mode
Floor temperature
Vacation temperature
mode
Automatic mode,
executes the
programmed schedules
Frost protection
activated
Decrease
Increase
O/RIDE
O/RIDE
Program
1,2,3,4
Program
1,2,3,4
+
AUTO
AUTO
RT
RT
FT
FT
–
General Settings
Press
buttton to Turn on/off the thermostat. When thermostat is turned off, the LCD will only display current temperature reading. When the thermostat is turned off,
press and hold button M for 3 seconds to bring up a confi guration menu. In this mode, press button M to select different features’ setting.
Menu # Features description
Features Explanation
Adjustment
(press up or down button to adjust)
01
Model (Model Selection)
This thermostat is a combination model allowing you to choose between
3 different models. A, AF and F model. A model: air only, with built in
sensor AF model: air & fl oor, with both built in and remote sensor F
model: fl oor only, with remote sensor
A, AF, F
02
Sd (switching differential)
The numbers of degree difference before switching. The default is 1°C
which means the thermostat will switch the heating on 0.5°C below the
set temperature and will turn it off 0.5°C above the set temperature. With
a 2°C differential, the heating will switch on 1°C below the set temperature
and will switch off 1°C above the set temperature.
1 = 1 degree(default), 2 =2 degrees
03
ATC (air temp calibrate)
This is to calibrate air temperature if required.
-1 = decrease 1 degree, 1 = increase 1 degree...
04
FTC (fl oor temp calibrate)
This is to calibrate fl oor temperature if required.
-1 = decrease 1 degree, 1 = increase 1 degree...
05
Maximum fl oor temperature
This is to protect the fl oor surface by limit the fl oor temp. (AF model only)
5s, 10s, 15s, 20s (default), 25s, 30s.
06
TR-AF (AF model only)
(TR=Temperature readout)
This gives option to choose to show air temperature,fl oor temperature or
to show both fl oor & air in interval.
A=to show air temperature, F=to show fl oor
temperature, A-F = to show both in 5 second intervals
07
MAXFT (set maximum
fl oor temp in AF model)
This is to protect the fl oor surface.
40 degree (default)
08
Clock format
This is to set the backlight turning-on time. User can also set the backlight
always on or off.
30 seconds (default) On= always on, OFF= always off
09
TF (temperature format)
This alows users to select between °C or °F.
°C or °F.
10
Clock
12/24-hour clock system selection
24 (default), 12- hour or 24-hour clock system
11
FP (Frost protection)
This is to avoid room temperature goes below 5°C
on= activated, off= deactivated
12
SC (setpoint confi guration)
This allows user to select between 2 sets of default programmed set points.
“4” means the 4 programmes will have 4 independent set
temperatures. Each set temperature can be different to the
others. program 3 ; set temperature in program 2 equals
the set temperature in program 4; If set temp in program
1 is changed, set temp in program 3temp in program 2 is
changed, set temp in program 4 will be changed will be
changed automatically to the same set temp as program 1.
If set automatically to the same set temp as program 2.
Please Note:
one of the following error messages will appear if one of these problems occur:
LO -
This error means that the room or fl oor temperature is below 0°C
HI -
This error means that the room or fl oor temperature is greater than 50°C
If the fl oor sensor is short-circuit or broken, the LCD will display “
ERR
” and the thermostat
will cut off output.
This product should be installed by a qualifi ed electrician.
www.
pro
warm
.com
support
0843 770 4597
Optional Remote
Controller Buttons
Optional Remote Controller
(Remote control model only)
1. Turn on/off thermostat
2. Confi rm setting
3. Program button
4. Lock or unlock buttons
5. Menu (in OFF mode)
6. Set Day
7. Set time
8. Auto / Manual selection
9. View fl oor temp (AF model only)
10. Cancel override
11. Vacation mode
12. Decrease the set value
13. Increase the set value
–
+
FT
FT
Run
Schedule
Run
Schedule
DAY
DAY
TIME
TIME
ENTER
ENTER
PROG
PROG
auto
auto
MENU
MENU
1.
3.
6.
9.
12.
2.
5.
8.
11.
13.
4.
7.
10.
SEE OVERLEAF FOR FURTHER SETTING UP INFORMATION