background image

 

54 

 

Manual 

 AlphaFreshbox 200 WiFi 

 

 12

 

Maintenance and servicing

 

Disconnect  the  unit  from  the  power  supply  before 
performing maintenance on the unit. 

 

Maintenance work is recommended 3-4 times a year. 
Maintenance of the ventilation unit includes regular cleaning 
of the unit surfaces from dust and filter replacement or 
cleaning. 

Maintenance of the ventilation system includes regular 
cleaning of the unit surfaces and filter replacement or 
cleaning. 

 

1. Filter maintenance (3-4 times per year) 

Dirty filters increase air 
resistance and reduce the 
supply air volume flow.  

Remove the dirty filters from 
the unit: 

Clean F7 filters with a hoover. 

To remove the G4 filters for 
cleaning, remove the flexible 
fixing clips. Rinse the filters 
with water and let them dry. 

Summary of Contents for AlphaFreshbox 200 WiFi

Page 1: ...AlphaFreshbox 200 WiFi With and without Radon sensor Manual March 2021 ...

Page 2: ...RadonTec GmbH Hauptstraße 5 89426 Wittislingen Germany Tel 49 9076 919 98 35 E Mail info radontec de Website radontec de Shop radonshop com Version 01 ...

Page 3: ...f delivery 11 5 Technical data 12 6 Dimensions 13 7 Design and operating logic 14 8 Assembly and operation 17 8 1 Mounting 18 8 2 Mains connection 25 8 3 Connecting additional control units 26 8 4 Control 28 Remote control 30 9 Emergency stop 51 10 Error codes warnings 52 11 Troubleshooting 53 12 Maintenance and servicing 54 13 Transport and storage 57 14 Disposal 58 15 Two year warranty 58 16 Sup...

Page 4: ...at recovery from the extract air to heat the supply air 2 Safety instructions Read the operating instructions carefully before using and installing the single room heat recovery unit Read the operating instructions carefully and keep them for as long as you use the AlphaFreshbox 100 WiFi When handing over the unit control the operating instructions must be handed over to the operator taking over t...

Page 5: ...e to follow the safety instructions may result in injury or equipment damage 2 1 Safety precautions during unit installation Before any installation or repair procedure the unit must be disconnected from the power supply The unit must be earthed Do not operate the unit outside the temperature range specified in the user manual or in aggressive or explosive environments Do not use damaged equipment...

Page 6: ... mains cable Do not place any heaters or other devices in the immediate vicinity of the mains cable of the unit All assembly and maintenance work may only be carried out by electricians with a valid electrical work permit for electrical work on the units up to 1000 V after carefully studying these operating instructions Make sure that the impeller and the housing are not damaged before connecting ...

Page 7: ...e sufficient air supply for proper combustion and exhaust of gases through the chimney of fuel burning appliances to prevent backflow The maximum permissible pressure difference per dwelling unit is 4 Pa The conveyed air must not be aggressive to steel at the temperature specified in the table in the Technical data section 2 2 Safety instructions for operating the unit Do not touch the controller ...

Page 8: ... place any containers with water e g vases on the unit Do not sit on the unit and do not place any objects on the unit All work on the electrical connections of the unit maintenance and repair work is only permitted when the unit is de energised Do not allow children to operate the unit Do not damage the mains cable while the unit is in operation Do not place any objects on the mains cable ...

Page 9: ...ontinuous operation check the mounting safety regularly Do not close or block the intake or exhaust air openings of the unit so as not to disturb the normal air flow Make sure that the air flow of the unit is not directed towards appliances with an open flame or candles The unit is not intended to be used by children physically or mentally handicapped persons persons with sensory disorders or pers...

Page 10: ...for energy efficient modern house construction The unit is a component of a ventilation system and is not designed for stand alone operation The unit is designed for continuous operation with a permanent power supply The conveyed medium must not contain explosive and flammable substances chemical vapours sticky substances fibrous materials dust soot oil particles and other harmful substances such ...

Page 11: ...ress of foreign bodies and water IP22 for the mounted ventilation unit IP44 for the motor units 4 Scope of delivery Please check the completeness of the scope of delivery using the following parts list 1x ventilation system 1x operating manual 1x Mounting template 1x Fastening set 1x Magnetic sheet 1x Key 1x spigot ...

Page 12: ... 10 W 15 W 25 W 44 W 134 W Power consumption of preheating coil 700 W Sound pressure level at a distance of 3 m 12 dBA 22 dBA 30 dBA 36 dBA 45 dBA Max Power consumption of the ventilation system 4 0 A Conveying medium temperature 15 to 40 C Material of the casing Painted steel Insulation 30 mm Efficiency of heat recovery 75 70 68 67 66 Type of heat exchanger Countercurrent heat exchanger ...

Page 13: ...13 Manual AlphaFreshbox 200 WiFi Heat exchanger material Enthalpy membrane Supply air filter G4 F7 H13 optional Exhaust air filter G4 Diameter of the connection spigot Ø 100 mm Weight 44 kg 6 Dimensions ...

Page 14: ...ed outdoors by the exhaust air fan via the exhaust air pipe The fresh outside air flows into the ventilation system and is cleaned in the supply air filter The air then continues to flow through the heat exchanger and is led into the room by the supply air fan In the heat exchanger the heat from the warm extract air is transferred to the cold outside air Here the two air flows are completely separ...

Page 15: ...matic protection against overheating of the heating coil AlphaFreshbox 200 WiFi is equipped with a pre heating coil If the supply air temperature is below 3 C the pre heating coil automatically heats the supply air so that the average temperature of the extract air downstream of the heat exchanger is not below 5 C The extract air fan runs on the heating coil The extract air fan runs at the maximum...

Page 16: ...ir spigot Ø 100 mm for the removal of air from other rooms for example the bathroom The connection piece is included in the scope of delivery The exhaust air grille must be closed with the magnetic plug included in the scope of delivery see Installation and preparation for operation ...

Page 17: ...nd operation Read these operating instructions carefully before installing the unit Sufficient maintenance access must be considered when mounting the unit The recommended minimum distances between the ventilation unit and the walls are as follows ...

Page 18: ...f the housing and malfunction of the unit 1 A drilling template for marking the holes is included Tape the template to the wall at the required height Use the template to mark the holes for the ventilation pipes the attachment of the unit and the outlet of the power cable Lay all cables and pipes to the installation site before starting the installation work 2 Remove the template and drill two cor...

Page 19: ...0 mm Insert the dowels Remove the perforated fields for the ventilation pipes from the template and reattach the template with the adhesive tape 3 Cut the ventilation pipes to the required length On the outside wall the ventilation pipe must protrude by the length required for mounting the outside ventilation bonnet A For details see the installation instructions for the ventilation bonnet The ext...

Page 20: ...mplate openings Fix the ventilation pipes inclined downwards by 3 mm with wedges to allow the condensate to drain off To install the ventilation system with a second room connection place the connection elbow in the hole prepared for it in the wall and fix it with wedges Connect the connection elbow to the air duct A ...

Page 21: ... template with installation foam After the foam has cured remove the template and remove the excess foam Cut off the protruding parts of the pipes so that they are flush with the inner wall 6 Inserting an additional exhaust vent remove the plug at the back of the unit To do this unscrew the screws remove the plug and fix the spigot in its place with the screws ...

Page 22: ...anger Loosen the fixing screws and remove the protective cover to access the fixing holes 8 Remove the F7 and H13 filters to gain access to the mounting holes 9 If an exhaust air spigot is fitted remove the protective cover and fit the magnetic plug to the exhaust air grille ...

Page 23: ... pieces into the corresponding ventilation pipes When laying the ventilation pipes observe a minimum slope of 3 mm Fasten the system with the screws supplied included in the scope of delivery The system is fixed with four screws Reinsert the filters the earthing cable and the protective covers into the ventilation system and close the access door of the system ...

Page 24: ...11 Insert the outer bonnet Remove the excess foam Fill the cavities between the ventilation pipe and the wall with a sealant Fix the outer bonnet to the outer wall of the building see assembly instructions for the outer bonnet min 3 mm ...

Page 25: ...attention must be paid to the maximum load current and the maximum wire temperature which depends on the conductor type insulation length and routing type A circuit breaker built into the stationary power supply network must be installed at the external input to interrupt the circuit in the event of a short circuit or overload The installation location of the line circuit breaker must be quickly a...

Page 26: ...ccess the control unit open the unit door remove the protective panel undo the screws securing the side wall andremoveit Connection of the automatic fire fighting system contact PK Remove the jumpers between the terminals 5 and 6 In case of fire the normally closed dry contact breaks the control circuit from the central fire fighting board and cuts off power supply to the unit ...

Page 27: ...l to the humidity sensor installed at the factory of a normally open contact for activating the Boost mode When the contact closes the unit switches to maximum speed Type of contact Conductor PK1 Contact of fire alarm shield N C 2 x 0 25 mm2 RH1 Contact of external sensor N O 2 x 0 25 mm2 The unit is not included in the delivery set ...

Page 28: ...28 Manual AlphaFreshbox 200 WiFi 8 4 Control The ventilation system is controlled via the control panel on the housing of the ventilation system via the remote control and via the app ...

Page 29: ...d operation is switched on off with the key For this operating mode the time must be set correctly in the app By default the control unit saves a time controlled operation with the factory settings The switch on button of the time controlled operation blocks the buttons for switching the ventilation levels and for switching the reheating on off Switching the WLAN module on off is done with the key...

Page 30: ...to run to cool down the heating coil The switch off time of the fans is 0 5 2 minutes depending on the model of the ventilation system Remote control Control via app on mobile device For Android in the Google Play Store https play google com store apps details id com embarca dero BlaubergFRESHBOX ...

Page 31: ...lauberg freshbox id1402506523 WiFi technical data Standard IEFE 802 11 g n Frequency band GHz 2 4 Transmission power mW dBm 100 20 Network DHCP WLAN security WPA WPA2 If the app is started without connecting to the system the following message is displayed on the screen of the mobile device ...

Page 32: ...r as indicated on the control board and the housing of the unit The default password of the WLAN access point 11111111 eight one Call up the installed app on the mobile device that is connected to the fan Select the desired connection type Call up the menu of the app Select the menu item Connection Home If the mobile device is connected to WLAN access point without router then select the default c...

Page 33: ...e network Select the connection with the required ID Edit the connection by pressing the button If necessary change the connection name enter the password of the system valid characters 0 9 a z A Z The default password of the system is 1111 four ones Confirm the entered data by pressing the key ...

Page 34: ...aFreshbox 200 WiFi Changing the password of the system Go to the menu Connection Home Select the connection and press the key Enter and confirm the password Valid characters 0 9 a z A Z Press the Change Password key ...

Page 35: ... displayed on the screen Select one of the WLAN modes Access point or Client Access point Access point without a home router In this mode up to 8 mobile devices can be connected to the fan to control it Select the desired security level for the Access point mode Open not password protected WPA PSK password protected WPA2 PSK password protected WPA WPA2 PSK password protected recommended ...

Page 36: ...for the client mode and the type of IP address Enter the name of the home router s WLAN access point Enter the password of the WLAN access point of the home router Select the type of IP address DHCP automatic assignment of the IP address when connecting to the home router recommended Static allows the IP address subnet mask and default gateway to be assigned manually These settings are only recomm...

Page 37: ... to edit the settings To switch to the special setup mode press and hold the Wi Fi button on the control panel of the ventilation unit for 5 seconds until the LED flashes The unit is in this mode for 3 minutes after which it automatically returns to the previous settings To exit the setting mode immediately press and hold the button again for 5 seconds until the LED stops flashing The following pa...

Page 38: ... to the home router from any distance with an Internet connection By default control via Cloud Server is switched off Activation is as follows Call up the menu item Connection Home Select the required connection type Call up the connection settings menu Activate the control via cloud server Warning If this function is activated WLAN connection faults of the home router can lead to temporary commun...

Page 39: ...New Account button Enter your login password and e mail address to re enter the password Confirm the entered data by pressing the key Follow the link that was sent via e mail Enter your login data and password and log in Add a new connection by pressing the button Enter the name of the ventilation unit and ID The ID number of the ventilation unit is indicated on the control board The default passw...

Page 40: ...40 Manual AlphaFreshbox 200 WiFi Confirm the entered data by pressing the key Press the key if necessary to log out ...

Page 41: ...41 Manual AlphaFreshbox 200 WiFi Menu structure ...

Page 42: ... server Filter change indicator Rotes Leuchten Alarmanzeige oranges Leuchten Warnanzeige Red light alarm indicator orange light warning indicator Heat dissipation indicator of the electric heating coil before the system is switched off Boost Boost operation indicator The current temperature of the sensor that controls the air temperature ...

Page 43: ...de in the menu Basic settings Timer Activation of timer controlled operation The settings for this mode are made in the menu Basic settings Timer menu Recirculation Activation of the recirculation mode If there is no recirculation mode the key is inactive Heating register Selection of the temperature setpoint for the post heating register or switching off the heating register ...

Page 44: ...r time Selection of the control temperature 15 С 30 С off are available If OFF is selected temperature control is not executed during timed operation Boost follow up time determines the follow up time for boost mode after the signal at the digital input boost switch on the control board disappears Boost switch on delay determines the switch off delay time for boost mode after the signal at the dig...

Page 45: ... weekends After activating the schedule in the Home menu the ventilation system runs according to the schedule according to the following parameters Ventilation level selection 1 5 Standby Time setting for a specific period of time Selection of the control temperature 15 С 30 С off are available If OFF is selected temperature control is not executed during timed operation ...

Page 46: ...e and time In this menu the current time and date are displayed and their settings are also made Time display format HH MM SS Date format DD MM YYYY Manual entry of date and time The same time as on the mobile device is set automatically ...

Page 47: ...pears and the corresponding filter change information is displayed in the alarm menu Total operating time shows the running time of the unit which cannot be reset Other The backlight changes dynamically after releasing the button the brightness decreases to a preset value Sound switches the loudspeaker on the board on off ...

Page 48: ...48 Manual AlphaFreshbox 200 WiFi Engineering menu Air flow rate Air flow rate preset ventilation level 1 5 and boost are set in this section ...

Page 49: ...status of all sensors Outdoor air temperature Supply air temperature Exhaust air temperature in front of the heat exchanger Exhaust air temperature behind the heat exchanger Firmware This menu shows the current version and date of the control unit and control panel firmware ...

Page 50: ... WLAN connection again Alarms Alarms and warnings are displayed in this menu Alarms are marked in red warnings are marked in black Alarm indicates a serious error in operation The ventilation system is forcibly switched off The alarm is reset manually with the Reset alarms button Warning the system is not forcibly switched off Warnings are automatically reset after the cause has been eliminated ...

Page 51: ...at exchanger is missing Short circuit on extract air sensor Exhaust air temperature sensor after the heat exchanger is missing Short circuit on the sensor after the heat exchanger in the extract air duct Reserved Reserved Sensor behind the heat exchanger in the supply air duct is missing Short circuit on the sensor after the heat exchanger in the supply air duct Empty battery The time controlled o...

Page 52: ...Wärmetauscher 8 Alarm Der Ablufttemperatursensor nach dem Wärmetauscher wurde nicht gefunden 9 Alarm Kurzschluss des Ablufttemperatursensors nach dem Wärmetauscher 10 Alarm Betätigung des Schutzthermostats des Vorheizregisters 11 Alarm Betätigung des Schutzthermostats des Hauptheizregisters 23 Warnung Der Akku ist leer Der zeitgesteuerte Betrieb wird nicht korrekt funktionieren 25 Alarm Feueralarm...

Page 53: ...icing If necessary switch off the ventilation system and allow the ice to melt Failure of the heating coil Contact your dealer Low flow rate Dirty filters fans and heat exchangers Clean or replace the filters clean the fans and the heat exchanger Clogged or damaged ventilation system Check for unobstructed opening of diffusers and louver shutters check the exhaust hood and the supply grille and cl...

Page 54: ...faces from dust and filter replacement or cleaning Maintenance of the ventilation system includes regular cleaning of the unit surfaces and filter replacement or cleaning 1 Filter maintenance 3 4 times per year Dirty filters increase air resistance and reduce the supply air volume flow Remove the dirty filters from the unit Clean F7 filters with a hoover To remove the G4 filters for cleaning remov...

Page 55: ...ntenance of the heat exchanger 1 time per year Even if the filters are cleaned regularly some dust may accumulate in the heat exchanger Therefore the heat exchanger must also be cleaned regularly for continued high efficiency Regular dry cleaning is recommended A hoover with a narrow suction nozzle is best suited for this Pull the heat exchanger out of the ventilation system clean it with a hoover...

Page 56: ...Maintenance of the supply air grille 2 times per year Leaves and other dirt can clog the supply air grille and reduce the delivery rate Check the condition of the supply air grille regularly and clean it of foreign objects as necessary 5 Maintenance of the ventilation pipes every five years Even if you carry out all the recommended maintenance regularly some dust may get into the ventilation pipes...

Page 57: ...g handling operations use lifting equipment to prevent possible damage The transport requirements for this type of cargo must be met Transport with vehicles of any kind must be carried out under constant protection against damaging mechanical and weather related influences Transport the unit only in the operating position Carry out loading and unloading operations carefully protect against shocks ...

Page 58: ...od of two years from the date of sale If a material or manufacturing defect occurs within the 2 year warranty the appliance will be repaired or replaced at our expense provided that the consumer complies with the regulations for transport storage assembly and operation The product complies with the European norms and standards the directives on low voltage and electromagnetic compatibility We here...

Page 59: ...ve parts or units of the unit The warranty does not cover parts of the unit that are subject to normal wear and tear e g filters and can therefore be regarded as wearing parts The warranty does not apply in the following cases The consumer does not present the fan in its entirety as specified in the operating instructions including the components of the unit disassembled by the consumer Non compli...

Page 60: ...r than that specified in the operating instructions Failure of the appliance due to voltage jumps in the mains Independent repair of the appliance by unauthorised persons Repairs to the unit by persons who are not authorised by the manufacturer Expiry of the warranty period of the unit Violation of applicable regulations concerning the transport of the appliance by the consumer Violation of regula...

Page 61: ...sented and that the warranty claim is made within the warranty period For the warranty repair the consumer must present the appliance the operating instructions with the note of the date of purchase and a payment receipt as confirmation of the purchase The model of the appliance presented must correspond to the model indicated in the operating instructions Contact the seller of the unit for warran...

Page 62: ...sked questions on our website https www radontec de 16 2 Contact Us Should you have any further questions or require further help and technical support please do not hesitate to contact us RadonTec GmbH Hauptstraße 5 89426 Wittislingen Germany Tel 49 9076 919 98 35 E Mail info radontec de Website radontec de Shop radonshop com ...

Page 63: ......

Reviews: