Re-Programming the Flash Chip
H A R D W A R E
R E F E R E N C E
Using phlash.exe to Re-Program the Flash Chip
1. Boot the EPC-6320/21 into MS-DOS with no memory managers running.
2. Copy the Flash Boot image to the system.
3. Start the re-programming process using one of these methods:
•
Run the phlash program using a command similar to this:
c:\phlash /mode=3
•
Run the update batchfile.
When finished, the phlash program displays a message, then automatically reboots
the system.
Note
For detailed information about creating a Flash Boot diskette, see
Before you Begin
on page 68.
Note
If using only console redirection, messages do not display. You must wait approximately three
minutes for the reflash to complete. The system automatically reboots when reflash is complete.