75
Beyond the Basics
4. Press
FUNC
then
2
. The display indicates
Custom Range
1/3
on fi rst line,
Base: 406.0000
on the second line,
Offset: 380
on the third line and
Step:25.0kHz
on the
bottom line.
5. While
B
in
Base
blinks, if necessary, press the
desired Base frequency with the number keys and
press
ENT
. Confi rm the entry. If it is incorrect, press
the number keys again to set the base frequency.
After you confi rm the input, press
ENT
again.
6. While
O
in
Offset
blinks, if necessary, enter the offset
number and press
ENT
. Confi rm the entry. If it is
incorrect, then press the number keys again to set
the frequency. After you confi rm the input, press
ENT
again.
7. While
S
in
Step
blinks, repeatedly press
e
or
d
to
select the step number, 5.0, 6.25, 10.0, 12.5, 15.0,
18.75, 20.0, 25.0, 30.0, 31.25, 35.0, 37.5, 40.0,
43.75, or 50.0 kHz, then press
ENT
.
8. Press
PROG
to enter the program mode. Store the
trunking IDs into the sub-bank in the same bank.
programming Motorola trunking systems (800
MHz)
Follow these steps to program 800 MHz band Motorola
trunking.
On the 800 MHz trunking band, you can select a
base frequency (normal or offset).
On the 900 MHz trunking band, you do not need to
set the base frequency (base, offset, step).
1. Press
PROG
then
TRUNK
to enter the ID program
mode.
Note
Note