Parameters of the hidden menu
Factory
value
Scope of
setting
Unit
DESCRIPTION
F01
3/6/9
3/6/9
-
Number of relay outputs supported by automation
system
F02
2,0
1,0-3,0
kW
Power of one heating element built-in in the boiler
F04
0
0 or 1
-
ROOM THERMOSTAT
0 –room thermostat is installed
1 –room thermostat is not installed
F05
0
0 or 1
-
ANTIFREEZE PROTECTION LIQUID
0 –antifreeze protection liquid is poured in
1 –antifreeze protection liquid is not poured in
F06
45
0 to 99
°C
Temperature at which the pump turns on
F07
3
0 to 99
°C
Minimum temperature of water in the boiler at which
the boiler starts up; if the water temperature is lower
than that set by parameter F07, it is impossible to turn
on the boiler.
F12
12
0 to 99
°C
Minimum value of temperature for alarm
F13
0
0 to 99
°C
Minimum value of temperature for blockade
F14
85
0 to 99
°C
Maximum value of temperature for alarm
F15
90
0 to 99
°C
Maximum value of temperature for blockade
F16
5
0 to 99
°C
Set temperature of water in boiler for antifreeze
protection mode
F19
3
0 to 6
kW
Boiler power in the antifreeze protection mode
F27*
15
0-99
°C
Difference (hysteresis) boiler and water heater (see
also the parameter F25)
F28
0,8
0-99
°C
Hysteresis for heating elements**
F29
0,4
0-99
°C
Hysteresis for heating elements ***
F30
3
1-20
min
Time of rotation of heating elements
F31
1
0 or 1
-
LANGUAGE
1-Serbian language and 0-English language