MAINTENANCE INSTRUCTIONS
35
REMOTE "OPEN THERM"
A
Se
Se
Ta
N
L
B
Ta
Outside
temperature
sensor (option)
cod. 40-00017
Ta
B
L
N
Ta
Se
Se
A
REMOTE "OPEN THERM"
Telephone control
cod. 40-00017
Connecting the remote controller and the outside temperature sensor (option)
Connect the wires to the terminal board inside the instrument panel as follows:
a.
switch off the power supply at the main
switch.
b.
remove the front case panel of the
boiler.
c.
slacken the screws and remove plate A
(see fig.1).
d.
remove jumper TA-TA from the terminal
board B;
e.
connect the remote controller wires.
When the wires have been connected,
place plate “
A
" back to position and then
the front case panel.
Connecting the remote controller and the telephone control (option)
Connect the wires to the terminal board inside the instrument panel as follows:
a.
switch off the power supply at the main
switch.
b.
remove the front case panel of the boiler.
c.
slacken the screws and remove plate A
(see fig.1).
d.
remove jumper TA-TA from the terminal
board B;
e.
connect the remote controller and the
telephone control wires;
f.
Active the telephone control through the
parameter no.16 (chapter 5.1
‘Parameters Table’)
When the wires have been connected, place
plate “
A
" back to position and then the front
case panel.
Fig. 2
Fig. 1