INSTALLATION INSTRUCTIONS
11
MIN.DISTANCES IN mm
H
A
X
L
Y
X
Y
L
H
1000
410
60
60
B
A
B
200
300
3.4
Installing the boiler
■
The appliance must be installed
exclusively on a flat vertical solid wall
capable of supporting its weight
.
■
The boiler should be fitted within the
building unless otherwise protected by a
suitable enclosure i.e. garage or outhouse.
(the boiler may be fitted inside a cupboard
.
■
If the boiler is sited in an unheated
enclosure then it is recommended to leave
the power on to give frost protection (frost
protection is active even with on/off switch
in off position).
■
If the boiler is installed in a room containing
a bath or shower reference must be made
to the relevant requirements.
Note: Flue Terminal Locations must
also comply with Section 6.9 of
AS/NZS 5601.1:2010
In order to allow access to the interior of the
boiler for maintenance purposes, it is important
that the necessary clearances indicated in
figure 1 are respected. To make the installation
easier, the boiler is supplied with a template to
enable the pipe connections to be positioned
prior to fixing the appliance to the wall.
To install the boiler, proceed as follows (see fig.
2):
a.
Use a spirit level (of not less than 25 mm
long) to mark a horizontal line on the wall
where the boiler is to be fitted.
b.
Position the top of the template along the
line drawn with the level, respecting the
distances indicated. Then mark the centres
of the positions of the two wall-plugs or
anchors. Finally, mark the positions of the
water and gas pipes.
c.
Remove the template and install the cold
water pipes, the gas supply pipe and the
central heating pipes using the fittings
supplied with the boiler.
Fix the boiler to the wall using the wall plugs or
bracket and connect the pipes.
Fig. 1
Fig. 2