2. FIRST START-UP
SUPPOR
T
C
ENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P13
HEATING FAN MAXIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE FAN
MAXIMUM SPEED IN HEATING PHASE, THAT CORRESPONDS
TO THE MAXIMUM BURNER POWER DURING A REQUEST
TO OPERATE IN HEATING MODE [SEE CHAPTER ‘HEAT
CAPACITY DIAGRAM (KW) –ELECTRIC FAN FREQUENCY
(HZ)’].
THE VALUE IS PRE-SET BASED ON THE SET POWER (SEE
PARAMETER P00) AND ON THE GAS TYPE (SEE PARAMETER
P02)
VALUE SET FOR
PARAMETER P12
- 203
THE VALUE IS EXPRESSED IN
HERTZ
(1HZ = 30 RPM)
P14
STARTING STEP ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE FAN SPEED
DURING START-UP
THE VALUE IS PRE-SET BASED ON THE SET POWER (SEE
PARAMETER P00) AND ON THE GAS TYPE (SEE PARAMETER
P02)
VALUE SET FOR
PARAMETER P10
- 203
THE VALUE IS EXPRESSED IN
HERTZ
(1HZ = 30 RPM)
P15
ANTI-LEGIONELLA FUNCTION
(ONLY FOR ACCUMULATION BOILERS)
THROUGH THIS PARAMETER YOU CAN ACTIVATE/
DEACTIVATE “ANTI LEGIONELLA” HEAT TREATMENT OF
THE ACCUMULATION BOILER. EVERY 7 DAYS THE WATER
TEMPERATURE INSIDE THE ACCUMULATION BOILER IS
HEATED BEYOND 60 °C THUS GENERATING A BURNING
HAZARD. KEEP UNDER CONTROL SUCH DOMESTIC
HOT WATER TREATMENT (AND INFORM THE USERS)
TO AVOID UNFORESEEABLE DAMAGES TO PERSONS,
ANIMALS, PROPERTY. A THERMOSTATIC VALVE SHOULD
BE INSTALLED AT THE DOMESTIC HOT WATER OUTLET TO
AVOID ANY BURNS.
0 - 1
0 = DISABLED
1 = ENABLED (PRE-SET BY
DEFAULT ON ACCUMULATION
BOILERS)