2. FIRST START-UP
SUPPOR
T
C
ENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P09
POST-CIRCULATION DOMESTIC / BOILER TIMING
THROUGH THIS PARAMETER YOU CAN SET THE PUMP
OPERATION DURATION ON THE DOMESTIC CIRCUIT, AFTER
THE TAP IS CLOSED.
0 - 90
VALUE EXPRESSED IN
MULTIPLES OF 5 SECONDS
(PRE-SET AT 18 X 5 = 90
SECONDS)
P10
FAN MINIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE FAN
MINIMUM SPEED THAT CORRESPONDS TO THE MINIMUM
POWER OF THE BURNER.
THE VALUE IS PRE-SET BASED ON THE SET POWER (SEE
PARAMETER P00) AND ON THE GAS TYPE (SEE PARAMETER
P02)
33 - VALUE SET FOR
PARAMETER P11
THE VALUE IS EXPRESSED IN
HERTZ
(1HZ = 30 RPM)
P11
FAN MAXIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE FAN
MAXIMUM SPEED THAT CORRESPONDS TO THE MAXIMUM
POWER OF THE BURNER. THE VALUE IS PRE-SET BASED
ON THE SET POWER (SEE PARAMETER P00) AND ON THE
GAS TYPE (SEE PARAMETER P02)
VALUE SET FOR
PARAMETER P10
- 203
THE VALUE IS EXPRESSED IN
HERTZ
(1HZ = 30 RPM)
P12
HEATING FAN MINIMUM SPEED ADJUSTMENT
THROUGH THIS PARAMETER YOU CAN SET THE FAN
MINIMUM SPEED IN HEATING PHASE, THAT CORRESPONDS
TO THE MINIMUM BURNER POWER DURING A REQUEST
TO OPERATE IN HEATING MODE. [SEE CHAPTER ‘HEAT
CAPACITY DIAGRAM (KW) – ELECTRIC FAN FREQUENCY
(HZ)’].
THE VALUE IS PRE-SET BASED ON THE SET POWER (SEE
PARAMETER P00) AND ON THE GAS TYPE (SEE PARAMETER
P02)
33 - VALUE SET FOR
PARAMETER P13
THE VALUE IS EXPRESSED IN
HERTZ
(1HZ = 30 RPM)