2. FIRST START-UP
SER
VICE
CENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P16
CLIMATE COMPENSATION CURVE
(ONLY WITH EXTERNAL PROBE CONNECTED)
YOU CAN CONNECT AN EXTERNAL TEMPERATURE
PROBE (SEE CHAPTER ‘ELECTRICAL
CONNECTIONS’) THAT AUTOMATICALLY CHANGES
THE DELIVERY TEMPERATURE BASED ON THE
EXTERNAL MEASURED TEMPERATURE. THE
NATURE OF THE CORRECTION DEPENDS ON
THE THERMO-ADJUSTMENT VALUE KD SET (SEE
CHART).
THE SELECTION OF THE CURVE IS DETERMINED
BY THE MAXIMUM DELIVERY TEMPERATURE TM
AND THE MINIMUM EXTERNAL TEMPERATURE TE
TAKING INTO ACCOUNT THE HOUSE INSULATION
DEGREE.
THE VALUES OF THE DELIVERY TEMPERATURES
TM, REFER TO STANDARD SYSTEMS 30-80 °C OR
FLOOR SYSTEMS 25-45 °C. THE SYSTEM TYPE CAN
BE SET FROM PARAMETER P03.
0 - 30
(SET BY DEFAULT AT 25) THE
NUMBERING OF THE VALUE
CORRESPONDS TO ‘KD’ CURVES
ON THE CHART (SEE CHART
BELOW).
P17
BOILER LOADING SETPOINT DIFFERENTIAL
(ONLY FOR THE VERSION WITH REMOTE STORAGE
SYSTEM).
BY MEANS OF THIS PARAMETER, IT IS POSSIBLE TO
SET THE PREVIOUS START VALUE FOR THE BOILER
ACCORDING TO THE SETPOINT OF THE DOMESTIC
CIRCUIT SET BY THE USER.
3 - 15
VALUE EXPRESSED IN °C (PRE-
SET TO 5°C)
Te (°C)
35
30
25
20
15
10
75
80
45 MAX
Tm (°C)
5
0
-5
-10
65
55
60
50
40
45
35
30
30
-15
-20
25 MIN
35
70
Kd = 0
Kd = 5
Kd = 10
Kd = 15
Kd = 20
Kd = 25
Kd = 30