15
1143923-W2-E
12.
Insert the wall plugs (supplied) and attach the
mixer to the wall or to the timber noggin with
the screws provided.
13.
Fit the compression nuts and olives onto the
pipework, connect the pipes and tighten the
compression nuts.
Important!
Make sure that the outlet pipework
protrudes through a Ø25 mm hole in the wall
or stud partition by approximately 40 mm and
temporarily cap off.
Note!
For stud partition installations where
access to the rear of the partition is possible,
fit the RAC wallplate over the outlet pipewor
k
on the inside of the partition.
For stud partition installations where access
to the rear of the wall is not possible, follow
instructions for solid wall installations, making
sure that suitable wall fixings (not supplied) are
used to secure the wallplate to the outside of
the stud partition.
14.
Turn on the water supplies and check for leaks.
15.
Determine the finished wall position (e.g. tile
thickness). Turn off the water supply, carefully
uncap the outlet pipe and cut to length, the
outlet pipe must protrude through the
finished
wall Exposed
by 21–23 mm.
Note!
Remove any burrs from the pipes before
proceeding.
16.
For solid wall installations or stud partition
installations
without
rear access go to
instruction 21.
For stud partition installations with access
to the rear of the partition continue with
instruction 17.
17.
Finish the wall (e.g. tiles).
Important!
Make sure that you use the
cardboard building-in shroud when finishing
the wall. This will protect the valve and make
sure that you tile up to the correct diameter.
Caution!
Make sure that the finished wall is
within the maximum and minimum limits and to
an even depth (no greater than 2 mm variation)
or the controls will not fit correctly.
18.
Fit the concealing ring over the mixer and mark
the positions of the three fixing holes.
19.
For solid walls drill three 6 mm holes for the
wall plugs. For other types of wall structure
alternative fixings may be required (not
supplied).
Caution!
Make sure that you do not drill into
pipework in the wall.
20.
Insert the wall plugs (supplied) and attach the
concealing ring to the wall with the screws
provided.
Important!
Apply silicone sealant to the
groove on the rear face of the concealing
ring
Screws
Outlet Pipe to Fittings
Hot Supply
Cold Supply
40 mm
RAC Wallplate
(shown fitted for rear
access stud partitions only)
Cardboard Building-in Shroud
Concealing
Ring
Apply Silicone
Sealant
Screws